LEO 6XRSm17/5-3 [4/10] Head of pump base
![LEO 6XRP18/14-11 [4/10] Head of pump base](/views2/1819901/page4/bg4.png)
Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11.
Type
3XRm2.5/16-0.55
3XRm3.5/16-0.75
4XRm4/10-0.75
4XRm4/14-1.1
Power
550 W / 0,75 HP
750 W / 1,0 HP
750 W / 1,0 HP
1100 W / 1,5 HP
Outlet diameter
1” / 1.25”
1” / 1.25”
1,25” / 1,5”
1,25” / 1,5”
Q. max
3,6 m
3
/h
5,4 m
3
/h
6,0 m
3
/h
6,0 m
3
/h
H. max
64 m
62 m
70 m
98 m
Max. immersion depth
80 m
80 m
80 m
80 m
Min. well diameter
3”
3”
4”
4”
Gross weight
15 kg
16 kg
17 kg
19 kg
Package
170x165x1200mm
170x165x1200mm
225x165x865mm
225x165x990mm
Selection of Pump
Condition of Deep Well
1..1
Requirements in the process of pumping
1..2
Well diameter and well depth
1..3
Static water level and dynamic water level of wen
1..4
Water Output and guarantee of water source
Calculation of Pump Total Head
Formula:
H=H +H +
V
2
+h
1 2 2g
H ---Total Head for the whole unit: (m)
H
1
---Vertical
distance
from
dynamic
water
level
to the
mouth
of
a
well
H
2
---Pressure value
in
the
outlet
of
pump
base
X
102.
It
is
pump
head.
V
2
/2
g
---Head of pump base
H ---Head loss in the pump pipe inside the well, refer to the table below
Pipe
Diameter
(mm)
Flow Rate(m
3
h)
3
4
5
6
7
8
9
10
12
14
16
18
20
25
Head Loss(m)
25
15.8
28
40
32
5
8.5
13
17.5
24
30
38
40
2.2
3.8
5.5
7.8
10.2
13
16.5
20
28
38
50
0.6
1
1.5
2
2.8
3.5
4.3
5.2
7.3
10
12.5
15.5
18.8
28.5
65
0.2
0.3
0.4
0.6
0.8
1
1.2
1.5
2
2.8
3.5
4.5
5.3
7.8
Содержание
- Borehole pump 1
- Instruction manual 1
- Congratulations on your purchase of a leo borehole pump 2
- Conditions of use 3
- Descriptions of model specification and performance 3
- General lntroduction 3
- A well 4
- Calculation of pump total head formula 4
- Condition of deep well 4
- Dynamic water leve 4
- H h h v2 h 4
- H head loss in the pump pipe inside the well refer to the table below 4
- H total head for the whole unit m 4
- Head of pump base 4
- Is pump head 4
- Pressure value i 4
- Pump bas 4
- Requirements in the process of pumping 4
- Selection of pump 4
- Static water level and dynamic water level of wen 4
- To the 4
- Vertical distanc 4
- Water output and guarantee of water source 4
- Well diameter and well depth 4
- Acquaer ltd h 4900 fehérgyarmat szatmári út 11 5
- Structure description 5
- This deep well submersible pump consists of pump working part pump power part submersible motor pipe part gate valve and control box etc connecting pump with motor with the shaft coupling to work under water see the figure below for its structure 5
- Installation use and maintenance 6
- Acquaer ltd h 4900 fehérgyarmat szatmári út 11 7
- Attachment of the heat shrink tubing 7
- Connection of the copper core cable heat 7
- Heat shrink tubing 7
- Insulation tape 7
- Shrink tubing copper core cable 7
- Waterproof tape 7
- Wrapping the insulation tape 7
- Wrapping the waterproof tape 7
- A suitable control 10
- Caused by an 10
- Check to see if it is 10
- Check to see if the 10
- Choose a suitable 10
- Contact 10
- Control box 10
- Motor is too low or tripping of the earth leakage protector 10
- So use a bigger diameter cable 10
- Symptoms main causes correction 10
- The hot resistance of the 10
- There is a phase failure or a poor 10
- Troubleshooting 10
- Undersized cable if 10
Похожие устройства
- LEO 6XRSm17/5-3 Каталог
- LEO 6XRSm17/5-3 Сертификат
- LEO 6XRSm17/7-4 Инструкция по эксплуатации
- LEO 6XRSm17/7-4 Каталог
- LEO 6XRSm17/7-4 Сертификат
- LEO 6XRSm17/9-5.5 Инструкция по эксплуатации
- LEO 6XRSm17/9-5.5 Каталог
- LEO 6XRSm17/9-5.5 Сертификат
- LEO 6XRS17/4-2.2 Инструкция по эксплуатации
- LEO 6XRS17/4-2.2 Каталог
- LEO 6XRS17/4-2.2 Сертификат
- LEO 6XRS17/5-3 Инструкция по эксплуатации
- LEO 6XRS17/5-3 Каталог
- LEO 6XRS17/5-3 Сертификат
- LEO 6XRS17/7-4 Инструкция по эксплуатации
- LEO 6XRS17/7-4 Каталог
- LEO 6XRS17/7-4 Сертификат
- LEO 6XRS17/9-5.5 Инструкция по эксплуатации
- LEO 6XRS17/9-5.5 Каталог
- LEO 6XRS17/9-5.5 Сертификат