Haier AU142AFBEA [233/365] Circuit dargrma of indoor unit

Haier AC182ACBEA [233/365] Circuit dargrma of indoor unit
>a__WcU[S^ <[c >a`V[e[a`Wc
FAN MOTOR
NOTE: Parts in dashed frame is not available
B:BLACK BR:BROWN W:WHITE GR:GRAY
R:RED Y/G:YELLOW/GREEN
SWING
MOTOR
T3.15A/250VAC
FAN MOTOR CAP.
0010573581
CONTROLLER
N
CN6
CN5
TRANS.
CIRCUIT DARGRMA OF INDOOR UNIT
TO OUTDOOR UNIT
W
B
WB
Y/G
TERMINAL
BLOCK
R
R
Y/G
CN7
S(N-W)
CN9
CN1
CN8
CN11
CN3
CN2
PIPING
TEMP
ROOM
TEMP.
FUSE
AP242/42NACBEA
0010575980
CN6
CN19
ROOM TEMP.
SENSOR
Y/G
Y/G
CN11
1
CN15
CN9
CN3
FUSE
CN12
T6.3A/250VAC
R
3
B
2
R
W
1
W
B
TRANS.
T3.15A/250VAC
REMOTE DETECTOR
CN2
CN20
TO OUTDOOR UNIT
PIPING TEMP.SENSOR
Y
BL
B
B
SWING MOTOR
Y
R
R
Y/G
1
Y/G
FAN MOTOR
FAN CAP.
BL
W:WHITE R:RED BR:BROWN GR:GREY B:BLACK
Y/G:YELLOW/GREEN
REMOTE RECEIVER
CN17
CN18
CN10
CN16
CN21
FAN MOTOR
NOTE:DASHED PART IS OPTIONAL
WIRING DIAGRAM OF INDOOR UNIT
FAN CAP.
AP88NACBEA
-233-

Содержание

Скачать