Haier AC092FEAHA [8/23] Important points of use
![Haier AE092FEBHA [8/23] Important points of use](/views2/1821873/page8/bg8.png)
Donít turn on or turn off the machine
with manual power switch
Donít
disconnect!
Turn on power supply of the outdoor
unit 12 hours in priority to running.
Switch on in priority
to running
Air quarding plate MUST be used
distinctively
In cool operation, wind outlet or surface of air
guarding plate may have moisture condensation
if the air-conditioner always drafts air downward
for a long period.(for cassette type)
Cool and heat operation cannot run at
the same time
For protection of outdoor unit, after long period
of shutdown, power of outdoor unit MUST be
switched on 12 hours in priority to running.
Donít disconnect the manual power switch during
usage of remote controller, operate with on/off
button on the controller.
All indoor subassembly cannot run heat and cool
operation at the same time and should be operated
with the same mode. (fan mode is an exception)
In heat operation, heat air may gather below the
ceiling and reduce heating effect if the air-
conditioner always drafts air upward for a long
period.
Apart from TV and radio receiver
Keep air-conditioner and its remote controller at
least 1 meter away from TV and radio receiver to
avoid unstable image on TV or noise in radio.
Important Points of Use
6
Содержание
- Ceiling concealed type 1
- Convertible type 1
- Duct type 1
- Four way cassette type 1
- Mrv intelligent network indoor air conditioner 1
- Split type 1
- Two way cassette type 1
- Cautions 2
- Disposal of the old air conditioner 2
- Disposal of the packaging of your new air conditioner 2
- Safety instructions and warnings 2
- Cautions 3
- Specifications 3
- Important points of safety 4
- Warning 4
- Important points of safety 5
- Warning 5
- Attention 6
- Important points of safety 6
- Air filer of cassette type 7
- Confirmation before running 7
- During cool operation 7
- During heat operation 7
- Heat ability 7
- Minutes protection 7
- Note confirm failure code shown on the remote controller shut down power switch and find out reasons after protection setting works check method as seen from check on page 21 continuous operation without solving problems can cause faults of the machine ensure air filter is installed without the filter dust may accumulate on heat exchanger and cause water leakage each indoor unit can run individually or many indoor unit run in meantime however heat and cool operation cannot be run at the same time 7
- Operation features 7
- Operation of fans of units that stop to protect units that stop during running of other indoor unit run their fans for 2 8 minutes at an interval of 30 or 60 minutes 7
- Power failure 7
- Protection setting high pressure switch 7
- Removal of frost in heat operation 7
- Air quarding plate must be used distinctively 8
- Apart from tv and radio receiver 8
- Cool and heat operation cannot run at the same time 8
- Donít turn on or turn off the machine with manual power switch 8
- Important points of use 8
- In cool operation wind outlet or surface of air guarding plate may have moisture condensation if the air conditioner always drafts air downward for a long period for cassette type 8
- In heat operation heat air may gather below the ceiling and reduce heating effect if the air conditioner always drafts air upward for a long period 8
- Turn on power supply of the outdoor unit 12 hours in priority to running 8
- Name of each part 9
- Name of each part 10
- Ae072feaha ae122feaha ae162feaha 11
- Ae072febha ae122febha ae162febha 11
- Ae092feaha ae142feaha ae182feaha ae242feaha 11
- Ae092febha ae142febha ae182febha 11
- Ae242febha 11
- Ae242flaha 11
- Ae242flbha 11
- Name of each part 11
- All content that can be shown on the display of remote controller are listed here to describe in details in practical use only content selected can be shown 12
- Auto high med low 12
- Besides this standard circuit controller ì timerî and ì central controllerî can also be used to practical control as seen from operation manuals attached with each remote controllers 12
- Central 12
- Contents that can be operated with standard remote controller yr e02 and central displays according to setting of central controller during central management with centralized controller yr e01 12
- Demand 12
- Display 12
- Display of ì centralî 12
- Duct type fix 12
- Filter 12
- Indoor unit display of fan 12
- Louver 12
- Manual 12
- Operation 12
- Operation guide 12
- Preheating defrost 12
- Running mode 12
- Stand by 12
- Switch over of fan speed 12
- Temperature setting 12
- Types other than of duct type 12
- Air filter reset button 13
- Fan button 13
- Lou button 13
- Mode button 13
- On off button 13
- Operation 13
- Operation guide 13
- Running indicator 13
- Running indicator goes out display for lou and running disappears while other displays still remain if the machine is stopped don t operate check switch except for check and repair of the machine 13
- Temp set button setting indoor temperature set temperature to desired degree within range of 18 c 29 c by pressing this button 13
- Timer button 13
- Operation guide 15
- Change 16
- Continuous 16
- How to set time 16
- Operation guide 16
- Power off in midway 16
- Preparation 16
- Release 16
- Setting of timer off run stop 16
- Setting of timer on stop run 16
- Timer off 16
- Timer on 16
- Timer operation 16
- Avoid overcooling and overheating 17
- Close doors and windows in time 17
- Cooling 17
- Heating 17
- Often clean air filter 17
- Operation guide 17
- Prevention of uneven indoor temperature 17
- Warning 17
- Adjustment of wind directions 18
- Auto wind board 18
- Four way cassette type 18
- Function of auto swing 18
- Two way cassette type 18
- Warning 18
- Adjustment of wind directions 19
- Convertible type 19
- Split type 19
- Ab092 122 142 162feai 20
- Ab092 122 142 162febia push the handle of inlet to side and open the inlet pull down air filter screen on the inside and take it out 20
- Ab182 242 282 322 362 452feai 20
- Ab182 242 282 322 362 452feaia push claws of the screen up then pull them to your side and take out the filter 20
- Cleaning of air filter 20
- Convertible type 20
- Daily cleaning 20
- Four way cassette type 20
- Maintenance 20
- Pull down the air filter screen and take it out 20
- Pull the air filter screen to your side and take it down 20
- Take the front panel and lift it up then pull it to your side finally pull it down and take out slowly the front panel can only be moved to one direction either left or right disassemble it after confirmation 20
- Two way cassette type 20
- Untie the ropes for falling proof at two ends 20
- Warning 20
- Daily cleaning 21
- Maintenance 21
- Check the following before entrusting any after service 22
- Indoor unit 22
- Machine still cannot run other than reason of protection setting 22
- Not fault 22
- Please recheck 22
- Stop running immediately disconnect manual power switch and consult after service in the following case 22
- Trouble shooting 22
Похожие устройства
- Haier AC092FEBHA Инструкция по монтажу
- Haier AC092FEBHA Инструкция по эксплуатации
- Haier AC122FEAHA Инструкция по монтажу
- Haier AC122FEAHA Инструкция по эксплуатации
- Haier AC122FEBHA Инструкция по монтажу
- Haier AC122FEBHA Инструкция по эксплуатации
- Haier AC162FEAHA Инструкция по монтажу
- Haier AC162FEAHA Инструкция по эксплуатации
- Haier AC162FEBHA Инструкция по монтажу
- Haier AC162FEBHA Инструкция по эксплуатации
- Haier AC182FEAHA Инструкция по монтажу
- Haier AC182FEAHA Инструкция по эксплуатации
- Haier AC182FEBHA Инструкция по монтажу
- Haier AC182FEBHA Инструкция по эксплуатации
- Haier AC242FEAHA Инструкция по монтажу
- Haier AC242FEAHA Инструкция по эксплуатации
- Haier AC242FEBHA Инструкция по монтажу
- Haier AC242FEBHA Инструкция по эксплуатации
- Haier AC282FEAHA Инструкция по монтажу
- Haier AC282FEAHA Инструкция по эксплуатации