Zotek ZT-M0 [2/3] Specifications

Zotek ZT-M0 [2/3] Specifications
- 5 - - 7 -
- 6 -
Specifications
AC
Voltage
V
6
.000V
0.001V
±
(1.0%+3)
600V
6
0.00V
0.01V
6
00.0V
0.1V
AC current
(mA)
9
99.9mA
0.1mA
±
(2.0%+3)
9
.999A
AC current
(A)
9
.999A
0.001A
DC
current
(mA)
999.9mA
0.1mA
±
(1.0%+4
9.999A
DC
current (A)
9.999A
0.001A
Resistanc
e
6
.000kΩ
0.001kΩ
±
(1.5%+3)
4
0MΩ
±
(1.0%+3)
6
0.00kΩ
0.01kΩ
6
00.0kΩ
0.1kΩ
6
.000MΩ
0.001MΩ
6
0.00MΩ
0.01MΩ
±
(1.5%+3)
Continuit
y/Diode
NCV
Temperatu
re
-20-1000/-4-1832 ±(3%+5
Frequency
response at AC modes 40Hz ~ 1kHz
Frequency
6
.000Hz
0.001Hz
±(1%+2)
10MHz
6
0.00Hz
0.01Hz
6
00.0Hz
0.1Hz
6
.000KHz
0.001KHz
6
0.00KHz
0.01KHz
6
00.0KHz
0.1KHz
6
.000MHz
0.001MHz
10.00MHz
0.01MHz
Test for temperature
1. Put the red lead to terminal and put the black
lead to COM terminal.
2. Push SEL/NCV four times to enter the temperature
mode.
3. Touch the probes to the desired test points.
4. Read the measured temperature on the display.
Bluetooth connect
1. Short push red button to open the Bluetooth function;
2. Open the E-bull app on the mobile , link this product
at the interface of the choosing multimeters;
3. Start testing, the value also show on the E-bull.
Capacitan
ce
6
.000nF
0.001nF
±
(5.0%+20)
4mF
6
0.00nF
0.01nF
±
(3.5%+4)
6
00.0nF
0.1nF
6
.000μF
0.001
μF
6
0.00μF
0.01
μF
6
00.0μF
0.1
μF
6
.000mF
0.001mF
±
(5.0%+5)
- 8 -
Test for capacitance
1. Connect the black test lead to the COM Terminal and
the red lead to the Terminal
2. Push SEL/NCV two times to enter the Capacitance
Mode
2. Connect the red probe to the anode side and the
black probe to the cathode side of the capacitor
being tested.
3. Read the measured capacitance value on the
display once the reading is stablized.
Test for frequency
1. Connect the black test lead to the COM Terminal and
the red lead to the Terminal
2. Push SEL/NCV three times to enter the frequency
Mode
3. Touch the probes to the correct test points of the
circuit to measure the frequency.
4. Read the measured frequency on the display
Test for NCV
1. Keep pushing the NCV button to enter the NCV
mode.
2. Hold the product and move it around, the built-in
beeper will beep when the inner sensor detects AC
voltage nearby. The stronger the voltage is, the
quicker the beeper beeps while the central LED light
will twinkle.
Test for Current
1. Put the red lead to terminal and put the black
lead to COM terminal. The current measure will be
auto matched when you put the leads in.
2. Touch the probes to the correct test points of the
circuit to measure the current.
3. Read the measured current on the display.
4. When you input the current over 2 AMP, the testing
time should be less than 3 seconds.
5. When the probes are in the current terminal but you
have no operations, this product will alarm each 4 seconds
to remind that you are in the current mode.
General Specifications
Display
6000 counts
Ture RMS
Ranging
Auto
Data Hold
Material
ABS
Backlight
Update Rate
3 / s
Flashlight
Low Battery
Indication
Auto Power
Off
Bluetooth
Environmental Specifications
Temperature
0~40
Humidity 75%
Temperature
-20~60
Humidity 80%
Electrical Specifications
Function
Range
Resolution
Accuracy Max
DC
VOLTAGE
V
6
.000V
0.001V
±
(0.5%+3)
600V
6
0.00V
0.01V
6
00.0V
0.1V
600V
LIMITED WARRANTY
AND LIMITATION OF LIABILITY
Customers enjoy one-year warranty from the date of purchase.
This warranty does not cover fuses, disposable batteries,
damage from misuse accident, neglect, alteration,
contamination, or abnormal conditions of operation or handling,
including failures caused by use outside of the product's
specifications, or normal wear and tear of mechanical
components.
Скачать