7.8. The dispenser must be calibrated during the tempering. It
is recommended to calibrate the dispenser depending on the
specific product, because specific weight may vary. For the
right calibration, the tank must be at least 75% full.
Press the Dispenser settings button (L). At the same time
press button (I) and keep both buttons pressed for about 5
seconds until display (G) shows:
(light weight)
Keeping the pedal pressed, collect the chocolate poured from
the machine with a container. Weigh the unloaded chocolate
and enter the net weight of the collected sample on the display
(A) by pressing the (H1) buttons. Press the (H2+) button until
it displays:
(bigger weight)
Keeping the pedal pressed, collect the chocolate the machine
will pour within a few seconds. Weigh the unloaded chocolate
and enter the net weight of the collected sample on the display
(A) by pressing the (H1) buttons.