Graco Reactor E-20 259034 [25/76] Repair

Graco Reactor E-20 CH9034 [25/76] Repair
Repair
312066ZAF 25
Repair
Before Beginning Repair
1. Flush if necessary; see Flushing, page 26.
2. Park component A pump.
a. Press .
b. Trigger gun until pump A stops. After fluid
pressure drops below 700 psi (7.9 MPa, 79
bar), motor will run until component A pump is
at bottom of its stroke, then shut off.
c. Check ISO reservoir for component A pump. Fill
wet cup on component B pump. Refer to your
Reactor system manual.
3. Turn main power OFF .
4. Perform the Pressure Relief Procedure.
Pressure Relief Procedure
1. Relieve pressure in gun and perform gun shutdown
procedure. See your gun manual.
2. Engage gun piston safety lock.
3. Close gun fluid manifold valves A and B.
4. Shut off feed pumps and agitator, if used.
5. Turn PRESSURE RELIEF/SPRAY valves (SA, SB)
to PRESSURE RELIEF/CIRCULATION .
Route fluid to waste containers or supply tanks.
Ensure gauges drop to 0.
6. Disconnect gun air line and remove gun fluid
manifold.
Repairing this equipment requires access to parts
that may cause electric shock or other serious injury if
work is not performed properly. Have a qualified
electrician connect power and ground to main power
switch terminals, see operation manual. Be sure to
shut off all power to the equipment before repairing.
ti2409a
SA
SB