Graco Reactor E-20 259034 — эффективная замена жидкости и обслуживание насосов [26/76]

Превью страниц Страница 26 / 76
Graco Reactor E-20 259034 [26/76] Pump removal
Repair
26 312066ZAF
Flushing
Flush out old fluid with new fluid, or flush out old
fluid with a compatible solvent before introducing
new fluid.
Use the lowest possible pressure when flushing.
All fluid components are compatible with common
solvents. Use only moisture-free solvents.
To flush feed hoses, pumps, and heaters separately
from heated hoses, set PRESSURE
RELIEF/SPRAY valves (SA, SB) to PRESSURE
RELIEF/CIRCULATION . Flush through bleed
lines (N).
To flush entire system, circulate through gun fluid
manifold (with manifold removed from gun).
To prevent moisture from reacting with isocyanate,
always leave the system dry or filled with a
moisture-free plasticizer or oil. Do not use water.
Pump Removal
NOTE: See your displacement pump manual for repair
instructions.
1. Shut off , , and heat zones.
2. Flush pump.
3. If pumps are not parked, press . Trigger gun
until pumps stop.
4. Turn main power off . Disconnect power
supply.
5. Shut off both feed pumps. Close both fluid inlet ball
valves (B).
6. Turn both PRESSURE RELIEF/SPRAY valves (SA,
SB) to PRESSURE RELIEF. Route fluid to waste
containers or supply tanks. Ensure gauges drop to 0.
NOTE: Use drop cloth or rags to protect Reactor and
surrounding areas from spills
Flush equipment only in a well-ventilated area. Do not
spray flammable fluids. Do not turn on heaters while
flushing with flammable solvents.
SA
SB
TI10954a
N
N
Pump rod and connecting rod move during operation.
Moving parts can cause serious injury such as
pinching or amputation. Keep hands and fingers away
from connecting rod during operation.
A
B
ti4147a
WLD
6%
6$

Содержание

160

Узнайте, как правильно заменить старую жидкость и обслуживать насосы. Следуйте инструкциям по промывке и обеспечьте безопасность при работе с оборудованием.