Graco Reactor E-20 GX9025 [28/76] Pump installation
Repair
28 312066ZAF
Pump Installation
Install Pump B
NOTE: Steps 1-5 supply to pump B. To reconnect pump
A, proceed to step 6.
1. Ensure locknut (G) is screwed on pump with flat
side up. Screw pump into bearing housing (M) until
pin holes align. Push pin (F) in. Pull retaining wire
clip (E) down.
2. Continue screwing pump into housing until fluid
outlet (D) is aligned with steel tube and top threads
are +/- 1/16 in. (2 mm) of bearing face (N).
3. Tighten locknut (G) by hitting firmly with a
non-sparking hammer.
4. Reconnect fluid inlet (C) and outlet (D).
5. To install pump A, see Install Pump A, .
6. If only one pump is installed, purge air and prime the
system. See Reactor operation manual.
C
D
F
E
G
M
N
1
TI3765a-1
Flat side faces up.
1
Lubricate threads with ISO
oil or grease.
2
2
2
2
3
Pump top threads must be
nearly flush with bearing face
(N).
3