Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Crossthreaded
CANcable.
CANcablescarry24Vdcpowerand
communicationbetweenmodules.
AcrossthreadedCANcable
connectormaycauseproblemswith
communicationand/orpowerto
modules.Carefullycheckforcross
threadedCANconnectionsonthe
TCMandonothermodules.
Softwaremismatch
betweenmodules.
Installinganewmoduleinthesystem,
orswappinginamodulefromanother
system,maycauseasoftware
mismatch.Updatesoftwareinall
modulesbyfollowingtheprocedurein
yoursystem'smanual.Makecertain
towaituntiltheuploadiscomplete
beforeremovingthetoken.For
moreinformationonloadingsoftware,
refertomoduleprogrammingmanual
3A1244.
No24VDCsupply
tomodule.
Greenlightoneachmoduleshouldbe
lit.Ifgreenlightisnotlit,checkto
makesureeachCANcableconnection
isnotcrossthreadedandistight.
Verifythepowersupplyisoutputting
24Vdc.Ifnot,checkpowersupply
wiring.Ifwiringisokay,replacethe
powersupply.
Moduledoesnot
havesoftware.
Insertasoftwareupgradetoken
intotheADMandcyclethepower.
Makecertaintowaituntiltheupload
iscompletebeforeremovingthe
token.Formoreinformationon
loadingsoftware,refertomodule
programmingmanual3A1244.
CACTTCMTCMCommu-
nicationError
Looseorbroken
CANcable.
ChecktheCANcablesrunning
betweenGCAmodules.Checkfor
crossthreadingandtightenifneeded.
Iftheproblemstillpersists,graspthe
cableneartheconnector,moveit
around,andwatchthe󰘱ashingyellow
lightontheGCAmodules.Ifthe
yellowlightstops󰘱ashing,replacethe
CANcable.