4. Maintenance
4.1 Maintenance
It is rec ommended, that you do a check once per week to evaluate lter element saturation.
To test water quality use test set. Instructions are attached in test set. Filter element must be
replaced when rst of the following parameters appears:
4000 operating hours of compressor.*
12 months regardless compressor operating hours.
Oil concentration in outlet reaches concentration determined with local directives and laws.
Damaged components are to be replaced by new ones. If a marked degree of damage is
found, the entire vessel is to be replaced.
Carry out a check for leaks once the maintenance work has been nished.
* At compressor oil carry over 2,5mg/m
³. Lower/higher oil carry over means proportionally longer/
shorter lifetime (e.g. if oil carryover is 5mg/m
³ lifetime reduces to 2000 operating hours).
Water quality can also be checked with “oil indicating test paper”. For test set please contact
us or your local distributor.
4.2 Replace lter element
Disposal of used separation elements must be carried out in
accordance with local regulations and laws.
To replace lter element follow this steps:
1. Remove protection foil from both lter bags, ll the cartridge with clean water. (Please pay
attention to warning specied in INSTALLATION chapter).
2. Close condensate inlet or make sure condensate will not be discharged into WOS during service.
3. Remove saturated lter element.
4. Clean connection for lter element on cyclonic depressurization chamber.
5. If necessary clean interior of cyclonic chamber.
6. Install NEW lter element to cyclonic chamber. Make sure that white lter element is
inserted in chamber 1 and carbon lter element is inserted in chamber 2.
7. Open inlet connection and put the unit in the operation.