25
- replace the possibly burnt fuse only with a 13 A ASTA approved fuse according to standard BS 1362; to replace
the fuse, in case of doubts, apply to a Skilled Technician or to a Qualied Electrician;
- reposition the cover in the correct way after replacing the fuse.
Use only Diesel for motor driving. e use of any other fuel can be dangerous.
During the operation, do not cover the water cleaner and do not place it where its ventilation could be impaired;
never cover the stack (28) emitting the boiler exhaust gases.
When you use the water cleaner in closet environments, make sure that the exhaust gases are evacuated in the correct
way and that there is a correct ventilation (poisoning danger).
Never bend onto the stack (28), nor touch it with bare hands (burning danger).
WARNING
If you use the water cleaner at room temperature that is higher than 40 °C/104 °F, do not let it directly under the sun.
If the water cleaner is used beyond 1000 m/3280 ft of height, apply to a Skilled Technician for a check and a possible
combustion adjustment.
5.1 pr e l I m I n a r y pr o c e d u r e s
Unroll the high-pressure pipe (7) completely.
If you have a model equipped with hose reel (4), unlock the device by rotating the ring nut in counter-clockwise
direction (3); unwind the hose quantity that you need, by rotating it in counter-clockwise direction by using
knob (5); lock the device by rotating the ring nut (3) in clockwise direction.
Fix a supply hose having an inner diameter of 18 mm/0.7 in. to the water suction connector (35), by tightening
with a suitable collar clamp. Operation D of Fig. 2.
Open the water supply tap, by paying attention that there is no dropping. Operation E of Fig. 2.
Make sure that the main switch (2) and the temperature adjusting knob (27) are set to o (position “0”) and
engage the plug in the power supply socket. Operation F of Fig. 2.
Set the main switch (2) to position “1”.
Press the cleaner guns control lever (24) and wait for a continuous jet of water to be issued.
Turn the main switch (2) to position “0” and connect the lance pipe (16)) to the cleaner gun (17).
5.2 st a n d a r d op e r a t I o n (h I G h p r e s s u r e ) W I t h co l d Wa t e r
Check that the temperature adjusting knob (27) is set to o (position “0”) and that the nozzle-holding head (18)
is not set to detergent supply (see also paragraph “Operation with detergent”).
Restart the water cleaner by setting the main switch (2) to “1” (2).
Note: during this restart phase, the high pressure cleaner will immediately stop operating after the initial peak,
as the Total Stop device will take eect.
Use the cleaner guns lever (24) to start operation of the high pressure cleaner and thus start cleaning.
e pressure value can be read on the pressure indicator (3).
5.3 st a n d a r d op e r a t I o n (h I G h p r e s s u r e ) W I t h ho t Wa t e r
WARNING
During the lling/topping-up operations of the gas oil tank, pay attention not to confuse the tanks. If you pour gas
oil into the detergent tank by mistake, do not use the water cleaner and apply to a Skilled Technician.
During the lling operations of the gas oil tank, pay attention not to pour liquid onto the water cleaner. In case this
happens, wait at least 24 hours before restarting the water cleaner, so that the fluid that has possibly entered the device
can evaporate.
Remove the plug (32) and by paying attention not to make the uid overow (we recommend to use a funnel
only for this operation), ll the tank (max. capacity of 20 l/5.3 US gal) with gas oil for motor driving; close the tank.
WARNING
e use of agricultural gas oil for heating or dirt causes excessive deposits onto the burner, thus impairing its good
operation.
Check that the nozzle-holding head (18) is not set to detergent supply (see also paragraph “Operation with
detergent”).
Restart the water cleaner by setting the main switch (2) to “1”.
Note: during this starting-up the water cleaner stops immediately after the starting pickup, because the Total Stop
device is activated.
Rotate the temperature adjusting knob (27) in order to select the wished temperature.