Before installing this product, please note the following safety information:
1. Always lower the leveling feet of the rack cabinet;
2. Always install equipment starting from the bottom of rack cabinet to top;
3. Always install the heaviest equipment in the bottom of the rack cabinet;
4. Always have two or more persons during assembling and moving the rack cabinet;
CAUTION:
OVERVIEW:
NOTE:Above products can be shipped in Build-up method or Knock-down/at-packed
method
Model No. Capacity(U) Width(mm) Depth(mm)
22U
42U
42U
47U
47U
AVAILABLE RACK DIMENSIONS BELOW:
RS SERIES FEATURE:
ATEN Racks are designed for mounting standard 19“ rack - mount equipment – servers,
routers, UPS systems, switches, audio/video devices – regardless of brand. All racks provide
straightforward equipment organization, excellent security and simple cable management
while enabling optimum airflow.
1. Hexagonal perforated front and back doors provide higher tensile strength than round holes
while ensuring efficient airflow and optimized ventilation
2. Static loading capacity up to 800KG
RS22U80
RS42U100
RS42U120
RS47U100
RE47U120
600
600
600
600
600
800
1000
1200
1000
1200
Содержание
- Rs series network rack 1
- Component list knock down 3
- Install front door rear door put the door block to the hole of the bottom of frame and set the front door rear door fix the top of front rear door by bolts and top of frame 3
- Install side panels adjust the diagonal dimension of cabinets remark because the cabinets is disassembled design after assemble please check and adjust the diagonal dimension ensure the space between doors are acceptable doors could open and close well 3
- Install the castors to the four corners at bottom by m6 12 self tapping screws install the m12 l90 leveling legs also to each corner 3
- Refer the left picture 3
- Refer the left upward view picture 3
- Step 4 3
- Step 5 3
- Step 6 3
- Rs series network rack assembly instruciton 4
- Step 1 4
- Step 2 4
- Step 3 4
Похожие устройства
- Aten UC8000 Краткое руководство по установке
- Aten UC8000 Руководство пользователя
- Aten StreamLIVE PRO UC9040 RESTful API Инструкция
- Aten StreamLIVE PRO UC9040 Руководство пользователя
- Aten StreamLIVE PRO UC9040 Краткое руководство по установке
- Aten StreamLIVE PRO UC9040 Руководство пользователя 2
- Aten CAMLIVE PRO UC3022 Краткое руководство по установке
- Aten CAMLIVE PRO UC3022 Руководство пользователя
- Aten CAMLIVE + UC3021 Краткое руководство по установке
- Aten CAMLIVE + UC3021 Руководство пользователя
- Aten StreamLIVE HD UC9020 RESTful API Инструкция
- Aten StreamLIVE HD UC9020 Руководство по программному обеспечению
- Aten StreamLIVE HD UC9020 Краткое руководство по установке
- Aten StreamLIVE HD UC9020 Руководство пользователя
- Aten CAMLIVE UC3020 Краткое руководство по установке
- Aten CAMLIVE UC3020 Руководство пользователя
- Aten US3342 Краткое руководство по установке
- Aten US3342 Руководство пользователя
- Aten US3344 Краткое руководство по установке
- Aten UH3239 Руководство пользователя