Enter the interface shown in Figure 6-36, select the disk to be used to configure RAID, [Enabled] means
selected, then select Apply Changes, and press Enter. If the status of the disk is JBOD or Unconfigured
Bad, it cannot be selected.
Figure 6- 36
g) Enter the interface shown in Figure 6-37, make corresponding settings (for parameter descriptions, see
Table 1-32), then select Save Configuration, and press Enter.
Figure 6-37 Set RAID parameters
Figure 6- 37
Parameter Description
Parameter
Description
Virtual Drive Name
RAID name, only supports letters, numbers and underscores, not case
sensitive
Virtual Drive Size
RAID capacity
Virtual Drive Size Unit
RAID capacity unit
Stripe Size
Stripe size, the size of the striped data block written on each disk
Read Policy
The read cache strategy is divided into Read Ahead (open read cache) and
No Read Ahead (close read cache)
Save)
Write Policy
Write caching strategy, divided into Write Through (write through mode),
Always Write Back (write back
Mode 1) and Write Back (write back mode 2)
I/O Policy
I/O strategy, divided into Cached (cache mode) and Direct (direct read and
write mode)
Access Policy
Read and write strategy, divided into Read/Write (read/write), Read Only
(read only) and Blocked (prohibited operation)