Chapter 8 Product Technical Specifications
8.1 Technical specifications
Features
Technical specifications
Model
2U
Size
2U cabinet type, maximum depth: 748 mm
Processor
Support 1 or 2 Intel Xeon Scalable series processors (up to TDP 165W, optional
TDP 205W)
Chipset
Intel C621/C622 series server dedicated chipset
RAM
Storage controller
Support DDR4 ECC RDIMM/LRDIMM server memory, memory frequency
support 1866/2133/2400/2666MHz Support 12 DDR4
Channel, each Channel supports 2 DIMMs, a total of 24 DDR4 slots; supports
Intel Optane 2933MHz memory
Internal storage controller: PCH supports RAID 0\1\10&5 External HBA (non-
RAID): 12 Gbps SAS HBA Internal storage: 2 PCIe
3.0 x4 M.2 slot, 2 Mini SSD slots (SATA DOM)
Driver
Support 8/12/25 hot-plug SAS/SATA(HDD/SSD)
Power supply
Platinum level 500W, 800W, 1200W, 1600W hot-swappable redundant power
supply, optional support 240V and 336V high voltage DC power supply, -48V
high voltage DC power supply
External
port&PCIE
Front port: VGA, 2 USB3.0
Rear: VGA, 2 USB3.0, 1 management network port, 2 RJ45 network ports
PCIE expansion board: up to 10 PCIE expansion slots OCP slot: 1 OCP 3.0 (X8)
System fan
Standard 4 8038 N+1 hot-swappable redundant fans, optional 4 8056 N+1 hot-
swappable redundant fans
Network
Onboard 2 1GbE or 10GbE (RJ45) TPM/TCM (optional)
Security
Chassis opening intrusion detection
Lock the upper cover of the chassis
Management
The onboard iBMC management module supports management features such
as IPMI, SOL, KVM Over IP, and virtual media
Operating system
Microsoft Windows Server , Red Hat Enterprise Linux , SUSE Linux Enterprise
Server , CentOS , Ubuntu
Virtualization
support
Citrix Xen Server , Vmware ESXi , Linux KVM , Windows Hyper-V
Temperature
Standard operating temperature: 10ºC-40ºC (without direct sunlight) Extended
operating temperature: 5ºC-40ºC (limited configuration meets)
Transportation storage temperature: 10ºC-40ºC
Humidity
Working humidity: 30%-80% (non-condensing) Storage humidity: 5%-95% (non-
condensing)
Table 1- 29
Содержание
227- User manual
- Purley platform 2u two way l shaped server barebones
- Preface
- Chapter 3 installing system components
- Chapter 1 security statement
- Chapter 5 bios parameter setting description
- Chapter 7 ipmi rapid deployment
- Chapter 6 raid setting instructions
- Chapter 2 product introduction
- Manual structure
- Chapter 8 product technical specifications
- Chapter 4 system cabinet installation
- Statement
- Product name purley platform 2u dual channel l shaped server barebone system manual version v1
- Trademark statement
- Disclaimer
- Copyright statement
- Glossary
- Symbol convention
- Contents
- To prevent the risk of major personal and property losses please follow the following recommendations
- General safety matters
- Chapter 1 security statement
- Warning notice
- Substances or elements
- Product name and content identification table of toxic and hazardous substances or elements
- Product name and content identification table of toxic and hazardous
- Climate and environmental requirements
- Other important description
- System configuration
- System parameters
- System introduction
- Chapter 2 product introduction
- System structure
- System model specification introduction
- 2u8 disk bay 3 inch disk model
- 2u12 disk bay 3 inch disk model
- System component introduction
- Front panel components
- 2u8 disk bay 3 inch disk model
- 2u12 disk bay 3 inch disk model
- Front panel interface description
- Description of front panel indicators and buttons
- Rear panel interface description
- Rear panel components
- Description of indicators and buttons on the rear panel
- Motherboard components
- Hard disk backplane assembly
- 2u12 expansion backplane as shown
- Serial number
- Sas sata backplane as shown
- Description features
- Serial number
- Description features
- U backplane as shown
- Description features
- Serial number
- Serial number
- Riser 1
- Description features
- Serial number
- Riser 2
- Description features
- Serial number
- Riser 3
- Description features
- Riser 4
- Description features
- Serial number
- Figure 2 22 hard disk label
- Dimm slot location
- Hard disk indicator
- System fan
- Cpu installation
- Install the processor
- Chapter 3 installing system components
- Installation steps
- Radiator installation
- Memory installation
- Hard disk installation
- Install 3 inch hard disk
- Install 2 inch hard drive
- Front hard disk backplane installation
- M ssd installation
- Pci e module installation
- Rear hard disk module backplane installation
- Rear hard disk module installation
- Rear 3 inch hdd tray installation
- Rear 2 inch hdd tray installation
- Power supply module installation
- Pci e expansion card installation
- Fan module installation
- Installation of air duct
- Cd rom installation
- Installation of the upper cover of the chassis
- Rail installation
- Chapter 4 system cabinet installation
- Install the outer rail to cabinet
- Install server to cabinet
- Navigation key description
- Chapter 5 bios parameter setting description
- Setup menu parameter description
- Enter the bios setup interface
- Memory information total memory
- Me firmware version
- Main menu description
- Usable memory
- Rc revision
- Processor type
- Platform information processor
- Cpld version
- Cpld name
- Build date and time
- Bmc firmware revision
- Bios information project version
- Access level
- System time
- System language
- System date
- Trusted computing
- Advanced menu description
- Serial port console redirection
- Console redirection settings
- Sio configuration
- Active serial port
- Option rom dispatch policy
- Pci subsystem settings
- Csm configuration
- Nvme configuration
- Network stack configuration
- Iscsi configuration
- Platform configuration menu
- Pch sata configuration
- Pch ssata configuration
- Usb configuration
- Miscellaneous configuration
- Runtime error logging
- Server me configuration
- Socket configuration menu
- Display cpu type id speed cache and other information configure cpu related functions display cpu type id speed cache and other information configure cpu related functions
- Intel txt function switch the menu options are
- Hyper threading control switch this option can enable or disable the intel processor hyper threading function enable this function each physical processor core is equivalent to two logical processor cores disable this function each physical processor core is equivalent to only one logical processor core enabling this feature will bring a higher processor core count and improve the overall performance of the application the menu options are
- Figure 5 24
- Figure 5 23
- Enable open
- Disable turn off default value enable
- Disable turn off default value disable
- Cpu virtualization technology switch enable this option then the virtualization layer or operating system that
- When starting a traditional operating system that cannot support extended cpuid the menu options are
- Processor configuration
- Pre socket configuration each slot configuration hyper threading
- Common refcode configuration
- Upi configuration
- Memory configuration
- Memory topology
- Memory map
- Memory ras configuration
- Static virtual lockstep mode
- Figure 5 30
- Iio configuration
- Advanced power management configuration
- Cpu p state control
- Hardware p state
- Figure 5 34
- Hardware pm state control
- Cpu c state control
- Package c state control
- Cpu advanced pm tuning
- Energy perf bias
- Server mgmt menu
- System event log menu
- Bmc network configuration menu
- View system event log menu
- Bmc user setting
- Add user
- Delete user
- Change user setting
- Security menu
- Boot menu
- User operation reminder
- Save exit menu
- Chapter 6 raid setting instructions
- Pch group raid
- Operation before group raid
- Configure raid in uefi boot mode
- Configure hot spare disk
- Delete raid
- Set rste working mode
- Configure raid in legacy boot mode
- Enter rste configuration interface
- Common tasks to configure raid
- Delete raid
- Lsi 9361 8i group raid
- Enter the raid card configuration interface
- Configure raid in uefi boot mode
- Common task switching disk mode
- Create raid
- Configure hot spare disk
- Enter the raid card configuration interface
- Configure raid in legacy boot mode
- Common tasks
- Chapter 7 ipmi rapid deployment
- Rapid deployment of ipmi process
- Make sure the motherboard supports ipmi function
- Enter bios to set ipmi function
- Ipmi interface configuration static mode
- Ipmi configuration java sol
- Enter the operation interface
- Ipmi function quick start instructions
- Ipmi management system content
- Start kvm remote management
- Introduction to kvm remote management
- Kvm page introduction
- Table 1 29
- Remote control quick operation
- Press enter to activate the screen
- Note the sol interface operation function has only tested the bios screen synchronization and other interfaces have not been tested this time is an operation demonstration and will not be described in detail
- Introduction to sol
- Figure 7 15 sol operation interface
- Figure 7 14 enable java sol
- Click activate java sol on the page shown in figure 7 14 to open the interface shown in figure 3 7
- After clicking activate the sol interface shown in figure 7 15 will appear
- Other ways to connect to ipmi
- Ipmi tools and other open source software
- Ipmi driver
- Technical specifications
- Chapter 8 product technical specifications
Похожие устройства
-
SNR SR2225RSРуководство пользователя -
SNR SR1204RSРуководство пользователя -
SNR SR1210RSРуководство пользователя -
SNR SR2208RSРуководство пользователя -
Supermicro SYS-7047GR-TRF, X9DRG-QF C602 Dual Xeon Socket2011 1866/1600/1333/1066/800MHz, up to 192GB DDR3 ECC Reg, 10xSATA, 1620WИнструкция по эксплуатации -
Supermicro SYS-7048R-TR, X10DRi C612 Dual Xeon Socket2011-3 2133/1866/1600MHz, up to 1TB DDR4 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-7048R-TRT, X10DRi-T C612 Dual Xeon Socket2011-3 2133/1866/1600MHz, up to 1TB DDR4 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-7047R-TRF, X9DRi-F C602 Dual Xeon Socket2011, 800-1600MHz, up to 512MB DDR3 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-5018R-МRИнструкция по эксплуатации -
Supermicro SYS-1028R-WC1RTИнструкция по эксплуатации -
Supermicro SYS-1028R-WC1RИнструкция по эксплуатации -
Supermicro SYS-1018GR-TИнструкция по эксплуатации