SNR SR2212RS — iPMI Management Interface Overview and Features [190/195]
Превью страниц
Страница 190 /
195
![SNR SR2225RS Руководство пользователя онлайн [190/195] 747303](/views2/1978639/page190/bgbe.png)
IPMI management interface menu description
(
1
)
dash board
On this page, users can view the basic information of the IPMI management system. Including
firmware information, network information, and sensor monitoring information.
The firmware information includes BMC firmware version information, BIOS version information,
motherboard CPLD version information, backplane CPLD version information, and BMC firmware
compilation time information.
The network information includes the MAC address of the system network and BMC network information.
You can choose to view the shared network port or dedicated network port of the BMC. BMC network
information includes BMC network MAC address information, IPV4 network mode information, IPV4 address
information, IPV6 network mode information, and IPV6 address information.
The sensor monitoring information will display the current alarm sensor information in real time,
including sensor name, sensor reading, real-time curve change of sensor reading, and alarm status.
(
2
)
sensor
This page displays the status of all sensors. When there is a sensor alarm, the sensor will be displayed
in the key sensor column. When the alarm is released, the sensor will be automatically removed from the
key sensor column.
(
3
)
System list
This page can view server CPU and memory information. In the block diagram, click the CPU block to
view the CPU information. The memory block is displayed in green to indicate that the memory exists. Click
the memory block to view the memory information.
(
4
)
Hard Disk Information
For the backplane with Expander, the green square means that the hard disk is in place, otherwise it
means it is not in place. You can view the status of the hard disk on the right or below the hard disk block.
Left click the green square to view the detailed information of the hard disk, and right click to locate the hard
disk.
(
5
)
Power consumption
Under this menu, the power consumption can be capped and the recent power consumption can also be
viewed.
(
6
)
FRU information
Select this menu to view the basic information of the FRU.
(
7
)
Log & Report
Under this menu, you can view the IPMI time log, audit log and video log.
(
8
)
Set up
You can configure some BMC under this menu. Including BSOD, date & time, network, etc...
(
9
)
remote control
On this page, you can start KVM, SOL, power control, UID (server indicator light) control.
(
10
)
Mirror redirection
On this page, you can get the latest image file on the remote storage device.
(
11
)
maintain
You can perform basic maintenance operations on the server, such as BMC firmware update, BIOS
firmware update
new.
(
12
)
Logout
Click to log out the current user's login.
Содержание
227- User manual
- Purley platform 2u two way l shaped server barebones
- Preface
- Chapter 3 installing system components
- Chapter 1 security statement
- Chapter 5 bios parameter setting description
- Chapter 7 ipmi rapid deployment
- Chapter 6 raid setting instructions
- Chapter 2 product introduction
- Manual structure
- Chapter 8 product technical specifications
- Chapter 4 system cabinet installation
- Statement
- Product name purley platform 2u dual channel l shaped server barebone system manual version v1
- Trademark statement
- Disclaimer
- Copyright statement
- Glossary
- Symbol convention
- Contents
- To prevent the risk of major personal and property losses please follow the following recommendations
- General safety matters
- Chapter 1 security statement
- Warning notice
- Substances or elements
- Product name and content identification table of toxic and hazardous substances or elements
- Product name and content identification table of toxic and hazardous
- Climate and environmental requirements
- Other important description
- System configuration
- System parameters
- System introduction
- Chapter 2 product introduction
- System structure
- System model specification introduction
- 2u8 disk bay 3 inch disk model
- 2u12 disk bay 3 inch disk model
- System component introduction
- Front panel components
- 2u8 disk bay 3 inch disk model
- 2u12 disk bay 3 inch disk model
- Front panel interface description
- Description of front panel indicators and buttons
- Rear panel interface description
- Rear panel components
- Description of indicators and buttons on the rear panel
- Motherboard components
- Hard disk backplane assembly
- 2u12 expansion backplane as shown
- Serial number
- Sas sata backplane as shown
- Description features
- Serial number
- Description features
- U backplane as shown
- Description features
- Serial number
- Serial number
- Riser 1
- Description features
- Serial number
- Riser 2
- Description features
- Serial number
- Riser 3
- Description features
- Riser 4
- Description features
- Serial number
- Figure 2 22 hard disk label
- Dimm slot location
- Hard disk indicator
- System fan
- Cpu installation
- Install the processor
- Chapter 3 installing system components
- Installation steps
- Radiator installation
- Memory installation
- Hard disk installation
- Install 3 inch hard disk
- Install 2 inch hard drive
- Front hard disk backplane installation
- M ssd installation
- Pci e module installation
- Rear hard disk module backplane installation
- Rear hard disk module installation
- Rear 3 inch hdd tray installation
- Rear 2 inch hdd tray installation
- Power supply module installation
- Pci e expansion card installation
- Fan module installation
- Installation of air duct
- Cd rom installation
- Installation of the upper cover of the chassis
- Rail installation
- Chapter 4 system cabinet installation
- Install the outer rail to cabinet
- Install server to cabinet
- Navigation key description
- Chapter 5 bios parameter setting description
- Setup menu parameter description
- Enter the bios setup interface
- Memory information total memory
- Me firmware version
- Main menu description
- Usable memory
- Rc revision
- Processor type
- Platform information processor
- Cpld version
- Cpld name
- Build date and time
- Bmc firmware revision
- Bios information project version
- Access level
- System time
- System language
- System date
- Trusted computing
- Advanced menu description
- Serial port console redirection
- Console redirection settings
- Sio configuration
- Active serial port
- Option rom dispatch policy
- Pci subsystem settings
- Csm configuration
- Nvme configuration
- Network stack configuration
- Iscsi configuration
- Platform configuration menu
- Pch sata configuration
- Pch ssata configuration
- Usb configuration
- Miscellaneous configuration
- Runtime error logging
- Server me configuration
- Socket configuration menu
- Display cpu type id speed cache and other information configure cpu related functions display cpu type id speed cache and other information configure cpu related functions
- Intel txt function switch the menu options are
- Hyper threading control switch this option can enable or disable the intel processor hyper threading function enable this function each physical processor core is equivalent to two logical processor cores disable this function each physical processor core is equivalent to only one logical processor core enabling this feature will bring a higher processor core count and improve the overall performance of the application the menu options are
- Figure 5 24
- Figure 5 23
- Enable open
- Disable turn off default value enable
- Disable turn off default value disable
- Cpu virtualization technology switch enable this option then the virtualization layer or operating system that
- When starting a traditional operating system that cannot support extended cpuid the menu options are
- Processor configuration
- Pre socket configuration each slot configuration hyper threading
- Common refcode configuration
- Upi configuration
- Memory configuration
- Memory topology
- Memory map
- Memory ras configuration
- Static virtual lockstep mode
- Figure 5 30
- Iio configuration
- Advanced power management configuration
- Cpu p state control
- Hardware p state
- Figure 5 34
- Hardware pm state control
- Cpu c state control
- Package c state control
- Cpu advanced pm tuning
- Energy perf bias
- Server mgmt menu
- System event log menu
- Bmc network configuration menu
- View system event log menu
- Bmc user setting
- Add user
- Delete user
- Change user setting
- Security menu
- Boot menu
- User operation reminder
- Save exit menu
- Chapter 6 raid setting instructions
- Pch group raid
- Operation before group raid
- Configure raid in uefi boot mode
- Configure hot spare disk
- Delete raid
- Set rste working mode
- Configure raid in legacy boot mode
- Enter rste configuration interface
- Common tasks to configure raid
- Delete raid
- Lsi 9361 8i group raid
- Enter the raid card configuration interface
- Configure raid in uefi boot mode
- Common task switching disk mode
- Create raid
- Configure hot spare disk
- Enter the raid card configuration interface
- Configure raid in legacy boot mode
- Common tasks
- Chapter 7 ipmi rapid deployment
- Rapid deployment of ipmi process
- Make sure the motherboard supports ipmi function
- Enter bios to set ipmi function
- Ipmi interface configuration static mode
- Ipmi configuration java sol
- Enter the operation interface
- Ipmi function quick start instructions
- Ipmi management system content
- Start kvm remote management
- Introduction to kvm remote management
- Kvm page introduction
- Table 1 29
- Remote control quick operation
- Press enter to activate the screen
- Note the sol interface operation function has only tested the bios screen synchronization and other interfaces have not been tested this time is an operation demonstration and will not be described in detail
- Introduction to sol
- Figure 7 15 sol operation interface
- Figure 7 14 enable java sol
- Click activate java sol on the page shown in figure 7 14 to open the interface shown in figure 3 7
- After clicking activate the sol interface shown in figure 7 15 will appear
- Other ways to connect to ipmi
- Ipmi tools and other open source software
- Ipmi driver
- Technical specifications
- Chapter 8 product technical specifications
Похожие устройства
-
SNR SR2225RSРуководство пользователя -
SNR SR1204RSРуководство пользователя -
SNR SR1210RSРуководство пользователя -
SNR SR2208RSРуководство пользователя -
Supermicro SYS-7047GR-TRF, X9DRG-QF C602 Dual Xeon Socket2011 1866/1600/1333/1066/800MHz, up to 192GB DDR3 ECC Reg, 10xSATA, 1620WИнструкция по эксплуатации -
Supermicro SYS-7048R-TR, X10DRi C612 Dual Xeon Socket2011-3 2133/1866/1600MHz, up to 1TB DDR4 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-7048R-TRT, X10DRi-T C612 Dual Xeon Socket2011-3 2133/1866/1600MHz, up to 1TB DDR4 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-7047R-TRF, X9DRi-F C602 Dual Xeon Socket2011, 800-1600MHz, up to 512MB DDR3 ECC Reg, 8xSATA3, 920W (1+1)Инструкция по эксплуатации -
Supermicro SYS-5018R-МRИнструкция по эксплуатации -
Supermicro SYS-1028R-WC1RTИнструкция по эксплуатации -
Supermicro SYS-1028R-WC1RИнструкция по эксплуатации -
Supermicro SYS-1018GR-TИнструкция по эксплуатации
Explore the IPMI management interface, including sensor monitoring, system information, power consumption, and remote control features for efficient server management.