Product Description
High Performance 10-20k UPS
8
1.5.4 Battery Charger
The battery charger utilizes energy from the DC bus and precisely regulates it to continuously charge
the batteries. The batteries are being charged whenever the UPS is connected to utility power.
1.5.5 DC-to-DC Converter
The DC-to-DC converter utilizes energy from the battery system and raises the DC voltage to the
optimum operating voltage for the inverter. The converter includes boost circuit which is also used
as PFC.
1.5.6 Battery
The 10K/20K Standard include value-regulated, non-spillable, lead acid batteries inside. To maintain
battery design life, operate the UPS in an ambient temperature of 15-25C.
1.5.7 Static Bypass
The UPS provides an alternate path for utility power to the connected load in the unlikely event of a
UPS malfunction. Should the UPS have an overload, over temperature or any other failure condition,
the UPS automatically transfers the connected load to bypass. Bypass operation is indicated by an
audible alarm and illuminated amber Bypass LED. To manually transfer the connected load from the
inverter to bypass, press the ON/OFF button once.
NOTICE:The bypass power path does NOT protect the connected equipment from disturbances in
the utility supply.
1.6 UPS Working Mode
Normally UPS working mode include normal mode, bypass mode, battery mode, ECO mode,
frequency converter mode, self aging mode.
Normal mode:
Shown as Fig 1-4, rectifier supply DC supply to inverter, the load is feed by inverter. Charger is
charging the battery.
TVS&RFI/E
MI filter
REC/PFC INV
CHG
BATT
BYPA
SS
input
Содержание
- Important safety instructions 1
- 危险 1
- 警告 1
- Battery 8 3
- Battery charger 8 3
- Controls and indicators 17 3
- Dc to dc converter 8 3
- Important safety instructions 1 3
- Installation 12 3
- Inverter 7 3
- Product description 3 3
- Rectifier power factor correction pfc circuit 7 3
- Static bypass 8 3
- Transient voltage surge suppression tvss and emi fri filters 7 3
- Annex a parallel setting 30 4
- Annex b mechanical size 31 4
- Annex c battery run time 32 4
- Control and communication 24 4
- Maintenance 26 4
- Operation 22 4
- Trouble shooting 28 4
- Electromagnetic compatibility 5
- Product description 5
- Appearance 6
- Features 6
- K 15 20k 6
- Models 6
- High performance 10 20k ups 7
- Product description 7
- Breaker 8
- Bypass breaker 8
- Cold start button 8
- Ground 8
- Intelligent 8
- Parallel option 8
- Protector 8
- Reserved 8
- Terminal 8
- Usb option 8
- Battery 9
- Input source 9
- Mi filter pfc inv 9
- Sps dsp 9
- System description 9
- Tvs rfi e 9
- Ups working mode 10
- Mi filter rectifier pfc inverter 11
- Tvs rfi e 11
- Mi filter rec pfc inverter 12
- Mi filter rectifier pfc inverter 12
- Product specification 12
- Tvs rfi e 12
- Connect input output power 14
- Installation 14
- Unpacking and inspection 14
- Connect parallel cables 16
- Operating procedure for connecting the long backup time model ups with the external battery 16
- Connect communication cables 17
- Output input 17
- Controls and indicators 19
- Operation 24
- Operation mode 24
- Parallel operation 24
- Control and communication 26
- Dry contact 26
- Snmp card 26
- 3 opened form common connection utility input is failure 27
- Control and communication 27
- Fig 5 2 connect to external power supply 27
- High performance 10 20k ups 27
- Mode mode 27
- Rs485 is optional funciton for user to integrated monitoring and communication rs485 snmp and dry contact are installed in one intelligent slot 27
- The remoted epo is located on the rear panel of ups shown as fig 1 2 it s normal closed if it s opened it will acivate epo function the ups will be shutdown 27
- Utility failure 27
- Battery disposal 28
- Battery maintenance 28
- Maintenance 28
- Checking ups status 29
- Precaution 29
- Rated parameters set on lcd 29
- Annex a parallel setting 30
- Trouble shooting 30
- Trouble shooting 31
- Annex a parallel setting 32
- Annex b mechanical size 33
- Trouble shooting 33
- 10k 180 60 30 24 20 16 13 10 8 7 34
- 10k 240 120 60 40 28 23 20 18 16 15 34
- 10k 360 180 110 60 42 30 26 23 21 20 34
- 10k 480 210 150 90 60 46 37 28 25 22 34
- 10k 60 25 16 10 7 6 5 4 3 2 34
- Annex c battery run time 34
- Mechanical size 34
Похожие устройства
- SNR UPS-ONPM-50SMX33 Паспорт
- SNR UPS-ONRT-090-15CMX33 Руководство пользователя
- SNR UPS-ONRT-040-10CMX33 Инструкция
- SNR UPS-ONRT-045-15CMX33 Инструкция
- SNR UPS-ONRT-200-25CMX33 Руководство пользователя
- SNR UPS-ONT-6000-INT Паспорт
- SNR UPS-BCRM-3000-S72 Паспорт
- SNR UPS-BCRM-3000-S72 Инструкция
- SNR UPS-LIRM-1000-PS Паспорт
- SNR UPS-LID-800 Паспорт
- SNR INV-800-SH Паспорт
- SNR INV-800-SH Руководство пользователя
- SNR PDU-BYPASS-06A01B Паспорт
- SNR INV-1000-SH Паспорт
- SNR INV-1000-SH Инструкция
- SNR UPS-LID-1000-XPS Паспорт
- SNR UPS-BCRM-2000-S48 Паспорт
- SNR UPS-BCRM-2000-S48 Инструкция
- SNR UPS-BCRM-1000-S24 Паспорт
- SNR UPS-BCRM-1000-S24 Инструкция