RME HDSP 9652 [43/75] Operation
![RME HDSP 9652 [43/75] Operation](/views2/2008003/page43/bg2b.png)
User's Guide HDSP System HDSP 9652 © RME
43
The HDSP 9652’s word clock input can be high-impedance or terminated internally, ensuring
maximum flexibility. If termination is necessary (e.g. because HDSP 9652 is the last device in
the chain), bring jumper X105 on the Expansion Board into position 75 Ohm.
In case the HDSP 9652 resides within a chain of devices receiving word clock, plug a T-adapter
into its BNC input jack, and the cable supplying the word clock signal to one end of the adapter.
Connect the free end to the next device in the chain via a further BNC cable. Remove jumper
X105 from the Expansion Board. The last device in the chain should be terminated using an-
other T-adapter and a 75 Ohm resistor (available as short BNC plug). Of course devices with
internal termination do not need T-adaptor and terminator plug.
23.3 Operation
The HDSP 9652's word clock input is active when Pref. Sync Ref in the Settings dialog has
been set to Word Clock, the clock mode AutoSync has been activated, and a valid word clock
signal is present. The signal at the BNC input can be Single or Double Speed, the Hammerfall
DSP automatically adapts to it. As soon as there is a valid signal at the BNC jack, AutoSync Ref
will display Word. This message has the same function as the green Lock LED, but appears on
the monitor, i.e. the user can check immediately whether a valid word clock signal is present
and is currently being used.
In the line Freq., the AutoSync Ref shows the frequency of the reference signal, measured by
the hardware. In this case the frequency of the current word clock signal is measured and dis-
played.
The word clock output of the Hammerfall DSP is constantly active, providing the current sample
frequency as word clock signal. As a result, in Master mode the provided word clock is defined
by the currently used software. In Slave mode, the provided frequency is identical to the one
present at the currently chosen clock input. When the current clock signal fails, the Hammerfall
DSP switches to Master mode and adjusts itself to the next, best matching frequency (44.1 kHz,
48 kHz etc.).
Содержание
- Dsp system hdsp 9652 1
- Hammerfal 1
- User s guide 1
- Driver installation and operation windows 2
- General 2
- Connections and totalmix 3
- Driver installation and operation mac os x 3
- Technical reference 4
- General 5
- Hdsp 9652 5
- User s guide 5
- Brief description and characteristics 6
- Introduction 6
- Package contents 6
- System requirements 6
- External connectors 7
- Hardware connectors 7
- Hardware installation 7
- Internal connectors 8
- Accessories 9
- Appendix 9
- Warranty 9
- Ce fcc compliance 10
- Iso 9001 10
- Note on disposal 10
- Driver installation and operation windows 11
- Hdsp 9652 11
- User s guide 11
- Driver and firmware 12
- Driver installation 12
- Driver update 12
- De installing the drivers 13
- Firmware update 13
- Configuring the hdsp 9652 14
- Settings dialog 14
- Clock modes synchronisation 16
- Operation and usage 18
- Playback 18
- Dvd playback ac 3 dts 19
- Channel count under wdm 20
- Notes on wdm 20
- Multi client operation 21
- Digital recording 22
- Channel count under asio 23
- General 23
- Operation under asio 23
- Known problems 24
- Synchronization 24
- Operation under gsif gigasampler interface 25
- Using more than one hammerfall dsp 25
- Digicheck 26
- General 27
- Hotline troubleshooting 27
- Installation 28
- Driver installation and operation mac os x 29
- Hdsp 9652 29
- User s guide 29
- Driver and flash update 30
- Driver installation 30
- Driver update 30
- Flash update 30
- Configuring the hdsp 9652 31
- Settings dialog 31
- Clock modes synchronisation 33
- Mac os x faq 35
- Midi doesn t work 35
- Round about driver installation 35
- Channel count under core audio 36
- Pci card and pci slot compatibility 36
- Repairing disk permissions 36
- Supported sample rates 36
- Hotline troubleshooting 37
- Various information 37
- Connections and totalmix 39
- Hdsp 9652 39
- User s guide 39
- Digital connections 40
- Word clock 41
- Cabling and termination 42
- Technical description and usage 42
- Word clock 42
- Operation 43
- Overview 44
- Totalmix routing and monitoring 44
- The user interface 46
- Elements of a channel 47
- Tour de totalmix 47
- Mute und solo 49
- Submix view 49
- Presets 50
- The quick access panel 50
- Preferences 52
- The monitor panel 52
- Editing the names 53
- Hotkeys 54
- Menu options 55
- Level meter 56
- Elements of the matrix view 57
- Operation 57
- Overview 57
- Totalmix the matrix 57
- Advantages of the matrix 58
- Asio direct monitoring windows only 58
- Totalmix super features 58
- Copy routings to other channels 59
- Delete routings 59
- Selection and group based operation 59
- Recording a subgroup loopback 60
- Using external effects devices 61
- Mapping 62
- Overview 62
- Totalmix midi remote control 62
- Operation 63
- Simple midi control 64
- Loopback detection 65
- Hdsp 9652 67
- Technical reference 67
- User s guide 67
- Tech info 68
- Digital inputs 69
- Digital outputs 69
- Technical specifications 69
- Digital 70
- Lock and synccheck 71
- Technical background 71
- Latency and monitoring 72
- Ds double speed 73
- Aes ebu spdif 74
- Block diagram hdsp 9652 75
Похожие устройства
- Native Instruments Komplete Kontrol A25 Руководство по эксплуатации
- RME ADI-6432 Руководство по эксплуатации
- RME ADI-2 Руководство по эксплуатации
- Sennheiser AB 3-B Руководство по эксплуатации
- Se Electronics X1 S Руководство по эксплуатации
- Se Electronics X1 A Руководство по эксплуатации
- Se Electronics V7 MC1 Руководство по эксплуатации
- Se Electronics SE 4ST Руководство по эксплуатации
- Se Electronics SE 2200 Руководство по эксплуатации
- ONSTAGE GPB4000 Руководство по эксплуатации
- Rode NT-USB Руководство по эксплуатации
- ROSS DMX SWITCH 12 Руководство по эксплуатации
- ONSTAGE GPB3000 Руководство по эксплуатации
- MOOG Sirin Руководство по эксплуатации
- MOOG Etherwave Theremin Plus Руководство по эксплуатации
- MLB EL-1500 DMX(AB-1500A) Руководство по эксплуатации
- RCF COMPACT M 06 Руководство по эксплуатации
- RCF C 5215-96 Руководство по эксплуатации
- RCF C 5212-64 Руководство по эксплуатации
- RCF C3110-96 Руководство по эксплуатации