L-ACOUSTICS LA4X [21/47] Operation

L-ACOUSTICS LA4X [21/47] Operation
LA4X_UM_EN_2.0 w w w . l - a c o u s t i c s . c o m 21
The table below describes the maximum number of enclosures a single LA4X amplified controller can drive.
Table 4: Maximum number of enclosures per LA4X
Technology
Loudspeaker
enclosure
Max number of connections
per output *
Max number of enclosures
per controller
Coaxial
5XT
4
16
8XT
2
8
Passive 12XT
1
4
Active 12XT
2
4
115XT HiQ
1
2
Constant
Curvature WST
ARCS
®
WIDE/FOCUS
1
4
ARCS
®
II
1
2
Variable Curvature
WST
KIVA KILO
2
8
KARA
®
2
4
KUDO
®
1
1
K2
1
1
Subwoofers
SB15m
1
4
SB18
1
4
* For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output.
For active loudspeakers, the value corresponds to the number of sections in parallel on the output.
3.4.5 L-NET cabling
The LA4X can be remote controlled over an Ethernet network (called L-NET) using LA NETWORK MANAGER
software (refer to the LA NETWORK MANAGER video tutorial).
To connect the LA4X to L-NET use the EtherCON connectors on the L-NET panel (see Figure 7). Each of the two
EtherCON connectors can be equally used as an IN or LINK connector.
Refer to the LA NETWORK MANAGER video tutorial for network setup (type of cables, physical connections,
network topology…).
4 OPERATION
4.1 Powering on, powering off, selecting the standby mode
Press the POWER key for one second to power on the controller, see Figure 11.
The controller goes through a 6-second start-up sequence coming with Initializing Controller displayed on the
LCD screen. The POWER LED turns off and then is lit in orange.
The controller is ready for use when the main screen is displayed and the POWER LED is lit in green (see
section 4.2.1).