Clock Mode
Sample Rate
Sets the currently used sample rate. Offers a central and comfortable way of configuring the
sample rate of all WDM devices to the same value, as since Vista the audio software is no
longer allowed to set the sample rate. However, an ASIO program can still set the sample rate
by itself.
During record/playback the selection is greyed out, so no change is possible.
Clock Source
The unit can be configured to use its own clock (Internal = Master), or one of the input signals
(Word, MADI, TCO, Sync In). If the selected source isn't available (No Lock), the unit will
change to the next available one (this behaviour is called AutoSync). If none is available then
the internal clock is used. The current clock source is displayed as Current.
Pitch
More information on Pitch is available in chapter 11.2.
Options
MADI In
Defines the input for the MADI signal. 'Optical' relates to the optical input, 'Coaxial' to the BNC
socket.
TMS activates the transmission of Channel Status data and Track Marker information from the
MADI input signal.
Auto activates redundancy operation. If the current input signal fails, the other input will be used
immediately, provided a valid signal is found there. Input also works as automatic input selec-
tion, in case only optical or coaxial is present as input signal.
MADI Out
Defines the format of the MADI output signal. MADI can be a 56 or 64 channel signal.
88.2/96 kHz
Sample rates higher than 48 kHz can be transmitted using the normal 48K Frame, or using a
native 96K Frame at the card's output.
Word Clock Out
The word clock output signal usually equals the current sample rate. Selecting Single Speed
causes the output signal to always stay within the range of 32 kHz to 48 kHz. So at 96 kHz and
192 kHz sample rate, the output word clock is 48 kHz.
MADI Input Status
Displays the state of the current input signal:
• Channel format (64 or 56 channels)
• Frame format (48K or 96K)
• Sample rate (measured)
• Active input (optical or coaxial)
Sync Check
RME’s exclusive SyncCheck technology provides an easy to use check and display of the cur-
rent clock status. The SyncCheck field indicates whether no signal (No Lock), a valid signal
(Lock) or a valid and synchronous signal (Sync) is present at each of the digital clock source
inputs.
Содержание
- Dsp system hdspe madi 1
- Hammerfal 1
- User s guide 1
- Driver installation and operation windows 2
- General 2
- Connections and totalmix 3
- Driver installation and operation mac os x 3
- Technical reference 4
- General 5
- Hdspe madi 5
- User s guide 5
- Brief description and characteristics 6
- Introduction 6
- Package contents 6
- System requirements 6
- External connectors 7
- Hardware connectors 7
- Hardware installation 7
- Accessories 8
- Internal connectors 8
- Warranty 8
- Appendix 9
- Ce fcc compliance 10
- Iso 9001 10
- Note on disposal 10
- Driver installation and operation windows 11
- Hdspe madi 11
- User s guide 11
- De installing the drivers 12
- Driver and firmware 12
- Driver installation 12
- Driver update 12
- Firmware update 13
- Configuring the hdspe madi 14
- Settings dialog 14
- Settings dialog pitch 16
- Clock modes synchronisation 17
- Operation and usage 18
- Playback 18
- Dvd playback ac 3 dts 19
- Multi client operation 20
- Notes on wdm 20
- Digital recording 21
- General 22
- Known problems 22
- Operation under asio 22
- Digicheck 23
- Using multiple hdspe madi 23
- Hotline troubleshooting 24
- Driver installation and operation mac os x 25
- Hdspe madi 25
- User s guide 25
- Driver and flash update 26
- Driver installation 26
- Driver update 26
- Firmware update 26
- Configuring the hdspe madi 27
- Settings dialog 27
- Clock modes synchronisation 29
- Mac os x faq 30
- Midi doesn t work 30
- Repairing disk permissions 30
- Round about driver installation 30
- Supported sample rates 30
- Using more than one hdspe system 31
- Various information 31
- Digicheck mac 32
- Hotline troubleshooting 32
- Connections and totalmix 33
- Hdspe madi 33
- User s guide 33
- Connections 34
- Headphones 34
- Madi i os 34
- Word clock 35
- Word clock input and output 35
- Technical description and usage 36
- Cabling and termination 37
- Operation 38
- Overview 39
- Totalmix routing and monitoring 39
- The user interface 41
- Elements of a channel 42
- Tour de totalmix 42
- Mute und solo 44
- Submix view 44
- Presets 45
- The quick access panel 45
- Preferences 47
- The monitor panel 47
- Editing the names 48
- Hotkeys 49
- Menu fader groups 50
- Menu options 50
- Level meter 51
- Elements of the matrix view 52
- Operation 52
- Overview 52
- Totalmix the matrix 52
- Advantages of the matrix 53
- Asio direct monitoring windows only 53
- Totalmix super features 53
- Copy routings to other channels 54
- Delete routings 54
- Selection and group based operation 54
- Recording a subgroup loopback 55
- Using external effects devices 56
- Ms processing 57
- Mapping 58
- Overview 58
- Totalmix midi remote control 58
- Operation 59
- Simple midi control 60
- Loopback detection 61
- Hdspe madi 63
- Technical reference 63
- User s guide 63
- Inputs 64
- Outputs 64
- Technical specifications 64
- Digital 65
- Madi basics 66
- Technical background 66
- Lock and synccheck 67
- Latency and monitoring 68
- Ds double speed 69
- Qs quad speed 70
- Steadyclock 71
- Terminology 72
Похожие устройства
- RME HDSPe AIO Руководство по эксплуатации
- RME HDSP 9632 Руководство по эксплуатации
- RCF C 5215-94 Руководство по эксплуатации
- Jedia JPA-1360B Руководство по эксплуатации
- IMAGE-LINE FL Studio 20 Producer Edition Руководство по эксплуатации
- DTS FOS 100 SOLO POWER FC Руководство по эксплуатации
- DTS FOS 100 SOLO POWER CT Руководство по эксплуатации
- DTS FOS 100 POWER FC Руководство по эксплуатации
- JBL PMB Pole Mount Bracket Руководство по эксплуатации
- JBL CONTROL 19 CST Руководство по эксплуатации
- JBL ASB6118 Руководство по эксплуатации
- K-ARRAY KK202K Руководство по эксплуатации
- K-ARRAY KK102 Руководство по эксплуатации
- K-ARRAY KAN200+ Руководство по эксплуатации
- K-ARRAY KJ50vb Руководство по эксплуатации
- K-ARRAY KA24 Руководство по эксплуатации
- Dsppa MP-8712 Руководство по эксплуатации
- DPA MMC4018 Руководство по эксплуатации
- CIOKS DC5 Link Руководство по эксплуатации
- CAMEO G Scan 80 LED Gobo Scanner 80W Руководство по эксплуатации