APart MA60 [10/28] Mixing amplifiers

APart MA60 [10/28] Mixing amplifiers
10
Mixing amplifiers
test button) on the paging mic input. Typically, 24 volt priority is
used to override volume controllers present on speaker lines.
7. Auto standby: set the switch to “enabled” to enable auto
standby.
8. Input 2: line level input on RCA connectors. Adjust the gain
potmeter so that the clip led does not light up when the signal
is at its highest level.
9. Pre-out: the pre-amp output carries the same line level signal
that is being fed to the power amplifier, i.e. the signal level is
determined by the position of the master volume control.
10. Mains inlet and mains power switch: connect the mains power
cord here. Switch on the power switch to power up the unit.
The mains fuse is also located here.
Note: emergency switch and the paging contact (and the chime
test button) will mute all lower priority input signals. MIC vox
will attenuate all lower priority input signals by 30 dB. This is also
known as “voice over circuit”.
The chime can only be activated by closing the paging contact (and
the chime test button) on the paging mic.
As long as the chime sounds (approx. 2 sec), the paging message
will be muted, even if the chime level is set to the minimum (off)
level.
When the priority output is activated and loaded with full power
(24V, 0.5A), please use at an interval of at least 10 minutes and
each time no less than 1 minute.