Instruction manualMA30 - MA60
11
IMPORTANT!
This amplifier relies on convectional cooling. In normal situations,
overheating will not occur due to the class-D amplifier topology.
Since there are no cooling fans in the amplifier, make sure the
convectional cooling system can work properly. The unit can be
built in a 19 inch rack system using the included 19 inch brackets,
but the ventilation holes should never be blocked. Therefore, it is
absolutely necessary to allow at least one free rack space or 44 mm
above the amplifier.
Make sure the ambient temperature is between 0 and 35°C.
Operating the unit beyond its normal limits may cause overheating.
If necessary, use a forced ventilation system in your mounting rack
when the rack holds multiple amplifiers.
The mains fuse is located in the mains inlet. When the fuse is
broken, replace it with a fuse of the same current and voltage
rating:
- MA30: T 1 AL / 250 V
- MA60: T 1.6 AL / 250 V.
For qualified personnel only!
Before using the amplifier for the first time, check the total
impedance of your speaker lines using an impedance meter:
temporarily disconnect the speaker line from the amplifier and
measure the speaker line. Minimum load impedance @ 100 volt
must be 167 ohms or more (MA60) or 333 ohms or more (MA30).
These values correspond to 60 and 30 watts @ 100 volt.