Eldes EWD3 белый AN-276741 [11/34] Temperature sensor
![Eldes EWD3 белый AN-276741 [11/34] Temperature sensor](/views2/1893747/page11/bgb.png)
11EN
EWD3 WIRELESS MAGNETIC DOOR CONTACT/SHOCK SENSOR/FLOOD SENSOR-READY
Supported zone mode combinaions and batery lifeime:
ZONE 1 ZONE 2
Magneic door contact
Shock sensor (up to 3 years)
Flood sensor (up to 4 years)
NO/NC sensor (up to 5 years)
EOL sensor (up to 2 years)
Tapparella (up to 3 years)
N/A (up to 5 years)
NO/NC sensor
Shock sensor (up to 3 years)
N/A (up to 5 years)
EOL sensor
Shock sensor (up to 2 years)
N/A (up to 2 years)
The batery operaion ime may vary under diferent coniguraion and condiions.
In case of tamper violaion, the alarm is caused regardless of system being armed or disarmed. There are 2 ways to detect tamper violaion on EWD3:
• By tamper switch. EWD3 comes equipped with a tamper switch intended for enclosure supervision. Once the enclosure of EWD3 is tampered, the
tamper switch will become triggered. By default, this acion will be followed by alarm, resuling in SMS text message delivery and/or phone call to the
user. The SMS text message contains the violated tamper name.
• By wireless connecion loss. The wireless connecion loss between EWD3 and ELDES alarm system leads to alarm. The system ideniies this event
as a tamper violaion and sends alarm by SMS text message and phone call to the user (-s) by default. The SMS text message contains the wireless
device model, wireless ID code and tamper name. The user will also be noiied by SMS text message as soon as the wireless signal is restored.
The tamper will not operate if both wireless zones are disabled.
For more details on EWD3 zone and tamper coniguraion, please refer to ELDES coniguraion sotware’s documentaion.
4. TEMPERATURE SENSOR
The device comes equipped with a temperature sensor allowing to monitor the temperature of the area surrounding EWD3 device. When using the device
paired with the alarm system, you may set the MIN and MAX temperature thresholds ranging from -20°C to +55°C (-4... +131°F) resuling in a noiicaion
delivery to the listed user and/or PGM output acion (turn ON/OFF; only on ESIM364 and ESIM384) once exceeded.
5. SHOCK SENSOR
EWD3 contains a built-in shock sensor (accelerometer) that detects the surface vibraions, such as drilling, knocking, hammering, of the locaion where the
device is installed. This feature allows to receive the alarm noiicaion in accordance with one of the selected sensiivity levels:
SENSITIVITY LEVEL DETECTION PROXIMITY
Low ~0,5m (~1.6t)
Medium ~1m (~3.3t)
High <2m (<~6.6t)
Custom for advanced users
Содержание
- User guide 1
- Hauptmerkmale 2
- Main features 2
- Pagrindinės savybės 2
- Основные свойства устройства 2
- Tamper 4
- Eol no nc 5
- Ewd3 wireless magnetic door contact shock sensor flood sensor ready 5
- Magnet 5
- Nc com 5
- Ewd3 wireless magnetic door contact shock sensor flood sensor ready 8
- Detector 9
- General operational description 9
- Configuring and pairing with the system 10
- Ewd3 zones and tamper 10
- Reset z com 10
- Tamper 10
- Shock sensor 11
- Temperature sensor 11
- Battery replacement 12
- Restoring default parameters 12
- Technical specifications 12
- Detector 15
- Лицевая сторона 15
- Описание принципа работы 15
- Reset z com 16
- Tamper 16
- Задняя сторона 16
- Зоны и тампер ewd3 16
- Настройки и программирование в охранную систему 16
- Датчик вибрации 17
- Температурный датчик 17
- Замена батареи 18
- Обнуление настроек 18
- Техническая спецификация 18
- Bendro veikimo aprašymas 21
- Detector 21
- Ewd3 zonos ir tamperis 22
- Konfigūravimas ir prijungimas prie apsaugos sistemos 22
- Reset z com 22
- Tamper 22
- Smūgio jutiklis 23
- Temperatūros jutiklis 23
- Baterijos keitimas 24
- Gamyklinių parametrų atstatymas 24
- Techninė specifikacija 24
- Allgemeine funktionsbeschreibung 27
- Ewd3 zonen und sabotagekontakt 28
- Konfiguration und verbindung mit der anlage 28
- Batterieaustausch 29
- Schocksensor 29
- Temperature sensor 29
- Technical specifications 30
- Wiederherstellung der standard parameter 30
Похожие устройства
- Volpi originale v.black vita 16 23VBE16 Инструкция по эксплуатации
- Volpi originale Powercut KV310 Инструкция по эксплуатации
- Laserliner ActiveFinder XP 083.013A Инструкция по эксплуатации
- KLPRO KLSS18BH-20 18 v / 2.0 ah li-ion 13993 Инструкция по эксплуатации KLSS18BH
- KLPRO KLSS18BH-50 18 v / 5.0 ah li-ion 13994 Инструкция по эксплуатации KLSS18BH
- KLPRO KLSS18BH-80 18 v / 8.0 ah li-ion 13995 Инструкция по эксплуатации KLSS18BH
- KLPRO KLSS18BHX-20 18 v / 2.0 ah li-ion 13996 Инструкция по эксплуатации KLSS18BHX
- KLPRO KLSS18BHX-50 18 v / 5.0 ah li-ion 13997 Инструкция по эксплуатации KLSS18BHX
- KLPRO KLMT18B-20 14006 Инструкция по эксплуатации KLMT18B
- KLPRO KLMT18B-50 14007 Инструкция по эксплуатации KLMT18B
- Cmt 800x600x930 мм 999.500.01 Инструкция к товару
- Cmt 800x600x930 мм 999.500.01 Инструкция к товару
- IQWATT для любого напольного покрытия IQ FLOOR CABLE 150 Вт - 7.5 м - 1 м.кв. 201 Инструкция по эксплуатации
- IQWATT для любого напольного покрытия IQ FLOOR CABLE 1800 Вт - 90 м - 12,0 м.кв. 213 Инструкция по эксплуатации
- IQWATT для любого напольного покрытия IQ FLOOR CABLE 2000 Вт - 100 м - 13,3 м.кв. 214 Инструкция по эксплуатации
- IQWATT для любого напольного покрытия IQ FLOOR CABLE 2200 Вт - 110 м - 14,7 м.кв. 215 Инструкция по эксплуатации
- IQWATT для любого напольного покрытия IQ FLOOR CABLE 600 Вт - 30 м - 4,0 м.кв. 206 Инструкция по эксплуатации
- IQWATT для любого напольного покрытия IQ FLOOR CABLE 700 Вт - 35 м - 4,7 м.кв. 207 Инструкция по эксплуатации
- Сем DT-8870 482629 Инструкция к товару
- TIELBUERGER TH80 AK-503-040TS Инструкция к двигателю