Ecosoft Absolute 5-50P с помпой на станине MO550PSECOEXP [27/292] Steps after installation

Ecosoft Absolute 5-50P с помпой на станине MO550PSECOEXP [27/292] Steps after installation
26 27
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2016
ENG
REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE
5. STEPS AFTER INSTALLATION
VERIFICATION OF THE UNIT’S OPERATING PARAMETERS
1. Measure me needed to ll the tank. Tank is lled when the dumping of the concentrate into
the drain has stopped. The value obtained is dependent on the supply water pressure (pressure
in water mains).
2. Measure recovery (proporon of supply water that becomes puried). You will need 1 L (1 quart)
measuring cup and a stopwatch.
Shut o tank valve 6, open faucet 3 and measure me that the unit takes to produce 1 L (1 quart) of
permeate (puried water), then close faucet 3. Write down the result (tPermeate in the equaon
below).
Disconnect the black tube connected to sink drain from drain saddle. Open faucet 3 and measure me
that the unit takes to produce 1 L (1 quart) of concentrate (waste water), then close faucet 3 and open
tank valve 6. Write down the result (tConcentrate in the equaon below). Calculate recovery using formula:
×100%
Where t is the number of seconds to obtain 1 L (1 quart) of water, R is recovery.
3. Measure TDS of supply water and TDS of puried water using a calibrated TDS meter.
4. Check if the auto shut-o valve funcons properly. Close tank valve 6 and faucet 3. The unit must
stop operang (water should stop being discharged to drain) within 10 minutes.
5. Check the unit for leaks.
6. Advise unit owner on lter maintenance and encourage to read this manual.
7. Make record of commissioning in the maintenance log in paragraph 9 of this book.
6. USAGE
Domesc reverse osmosis system is designed for puricaon of cold water only.
If the lling me of the tank increased, this means that the pre-lter cartridges are worn out and
should be urgently replaced. Delay in the replacement of cartridges can lead to deterioraon or
destrucon of the membrane.
To aviod such crical situaons, it is strongly recommended that you change pre-lter cartridges at
least once every 3 months.
If the rate of ltraon drops signicantly and is not helped by replacing pre-lters, you need to
replace reverse osmosis membrane.
To enjoy puried water of consistent quality, it is recommended to replace the membrane at least
once in 1-1.5 years.
In case of prolonged downme (2 weeks or more), it is necessary to sanize the system as described
in paragraph 7.
If you plan on leaving for an extended while, it is recommended to shut o the water supply.