Ecosoft Absolute 5-50P с помпой на станине MO550PSECOEXP [30/292] The procedure for replacing membrane

Ecosoft Standard с минерализатором [30/292] The procedure for replacing membrane
30
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2016
REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE
1.
Turn o water supply to the system (feed valve 5), shut o the tank valve 6.
2. Open the puried water faucet 3 to relieve permeate pressure.
3.
4.
5.
Disconnect the white tube from the inlet in membrane housing cap.
Unscrew the membrane housing cap.
Remove the used reverse osmosis membrane 11 (remember which end of the membrane goes where).
6. Lubricate rubber seals of the fresh replacement membrane and membrane housing cap sealing.
CAUTION! To avoid damage to the membrane, only use food grade glycerol as lubricant.
7. Install the fresh membrane into the housing, observing its direcon and posion of the tube.
CAUTION! Cut the plasc bag to install the reverse osmosis membrane. Install the membrane without rst unpack-
ing it by pushing it into the housing directly from the bag. Avoid touching the membrane and only hold it covered
with the bag.
8. Screw on the housing cap.
9. Connect the white tube to the membrane housing inlet.
10.
Close drinking water faucet 3.
11.
Open the tank valve 6.
12.
Open the feed valve 5.
13. Once the tank is full (you will hear the water stop owing), drain all water from the tank into the sink by opening
faucet 3. When the water stops running, close the puried water faucet 3 so that the tank starts to re-ll. Depending
on the pressure in your water mains, lling may take 1.5 to 3 hours. Aer the second tank re-ll, you can safely use
the puried water.
6. USAGE
6.3 THE PROCEDURE FOR REPLACING MEMBRANE
(membrane replacement should be performed by a qualied specialist)
Membrane
Cap of the membrane
housin
White tube