TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Fing leak Tube is not joined ghtly Remove and rejoin the tube
Drain saddle leak Drain saddle is not installed
properly
Reinstall drain saddle as described in paragraph
4.2 in this manual
Pre-lter sump leak O-ring seal is lacking or misaligned Check that the O-ring seal is properly aligned in the
groove inside sump
Sump is not joined ghtly Tighten the sump ll snug
Water runs too slowly from
the faucet or slows down sub-
stanally a few seconds aer
the faucet is opened
Water supply pressure too low This RO system requires at least 3 bar to funcon
properly. If necessary, install a pressure booster
pump or consult a plumber
Pre-lter cartridges are clogged Replace pre-lter cartridges
Membrane is clogged Measure permeate owrate by closing tank valve
6 and opening faucet 3. Use a measuring cup to
check if the me it takes to produce 1 L drinking
water is as follows:
– 8 minutes with 50 gpd membrane;
– 5-6 minutes with 75 gpd membrane;
– 4 minutes with 100 gpd membrane.
If it took twice as long or more to produce 1 liter
of water, the membrane may need to be replaced
(refer to the store where you bought this product)
A tube is kinked Straighten the tube
Pressure tank is deated Pressure in the empty tank should be 0.4-0.6 bar
(6-9 psi). Charge the tank to the above pressure
High noise
Air in the auto shut o valve The air will go away by itself with connued
operaon of the system
Water supply pressure too high Check your water supply pressure. If necessary,
install a pressure regulator or refer to a plumber