Ecosoft Absolute 5-50P с помпой на станине MO550PSECOEXP [31/292] The procedure for replacing carbon post filter and or mineralizing post filter

Ecosoft Absolute [31/292] The procedure for replacing carbon post filter and or mineralizing post filter
30 31
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2016
ENG
REVERSE OSMOSIS SYSTEM INSTALLER AND USER GUIDE
6. USAGE
1.
Turn o water supply to the system (feed valve 5), shut o the tank valve 6.
2.
Open the puried water faucet 3 to relieve permeate pressure.
3.
4.
5.
6.
7.
Disconnect the tubes that connect the carbon post lter / mineralizing
post-lter to the rest of the system (remember which goes where).
Remove the used carbon post-lter / mineralizing post-lter from clip
brackets.
Install new carbon post-lter / mineralizing post-lter, guided by arrows
that indicate the direcon of water ow.
Connect the tubes to the new carbon post-lter / mineralizing post-l-
ter to connect it to the system.
Open feed valve 5. Open tank valve 6.
9. Once the tank is full (you will hear the water stop owing), drain all water from the tank into the sink by opening
faucet 3. When the water stops running, close the puried water faucet 3 so that the tank starts to re-ll.
Depending on the pressure in your water mains, lling may take 1.5 to 3 hours. Aer the second tank re-ll, you can safely
use the puried water.
6.4 THE PROCEDURE FOR REPLACING CARBON POST-FILTER AND/OR
MINERALIZING POST-FILTER
6.5 THE PROCEDURE FOR REPLACING UV LAMP
(UV lamp replacement should be performed by a qualied specialist)
Recommended life of the UV lamp is 9000 hours (approximately 1 year of connuous operaon).
CAUTION!
Using UV lamp beyond the recommended service life is disapproved, since the intensity of UV
radiaon and its germicidal eciency will be reduced.
It is strongly forbidden to turn on the UV lamp power when the lamp is not in metal housing, and
to look at a glowing lamp. This can lead to eye damage and result in deterioraon or loss of vision.
When replacing the UV lamp, it is advisable to clean the quartz sleeve. Do not use abrasive mate-
rials to clean the sleeve, as this may decrease transparency of the sleeve to UV radiaon, thereby
reducing the eciency of disinfecon. Be careful when removing the quartz sleeve from the housing
to avoid damaging or scratching the sleeve.

Содержание