Connection to water supply
Pleasepayattentiontotheregulationsofyourwaterworkscompany!Inaccordance
withDINEN61770,themachinemaynotbedirectlyconnectedtothepublicdrinking
watersupplylines.AbriefconnectionhoweverispermissibleaccordingtoDVGW
(GermanAssociationforGasandWaterAffairs)ifatubeventilatorwithcheckvalve
(KränzleOrder-No.41.0164)isbuiltintothewatersupply.Alsoindirectconnectionto
thepublicdrinkingwatersupplylinesispermissiblebywayoffreeemissionin
accordancewithEN61770;e.g.byusingareservoirwithafloatvalve.Direct
connectiontoanon-drinkingwatersupplylineispermissible.
Safety notes - This is prohibited!
Electrical connection
Thevoltagegivenonthespecificationplatemustmatchthemains
voltage.
The machine is supplied with power cable without plug. The plug has to be equip-
ped with a safety earth terminal and a 30 mA residual-current circuit breaker.
The mains connection has to be fused with a time-delay fuse according to the
specifications on page 6/7.
Ifanextensioncableisused,itmusthaveanearthlinethatisproperlyconnectedtothe
plugconnections.Theconductorsintheextensioncablemusthavethefollowingmini-
mumcrosssection:
at 18 kW - 6 mm
2
at 24 kW - 10 mm
2
at 36 kW - 16 mm
2
at 48 kW - 25 mm
2
Extension cables that are too long cause a drop in voltage and thus
malfunctions. If you are using a cable drum, the cable must always
be fully unwound.