Kranzle Therm 891 E-ST 48 [21/64] Care and maintenance

Kranzle Therm 891 E-ST 48 [21/64] Care and maintenance
21
Change the oil:
Firstoilchangeafterapproximately
50 operating hours.Thereaftertheoil
shouldbechangedevery500operating
hoursoryearly.
Taketheoildrainagehose,whichis
connectedtotheoildrainagescrewfromthe
insideoftheappliance.
Opentheredoilllerplugatthetopsideof
theblackoilhousing.
Openthecapattheendofthehose.Drain
offtheoilintoanoilpananddisposeofit
responsibly.Closetheendofthehose.Rell
withnewoil.
Weekly, or after approx. 40 hours of operation:
-Checktheoillevelofthehighpressurepump.Iftheoillevelistoolow,addoiluntil
theoillevelisbetweenthetwomarkingsontheoilmeasuringrod.
Changetheoilifithasagreyorwhitishappearance.Theoilshouldbe
disposedofresponsibly.
-Checkthewaterfilterinfrontofthefloatvalveinthewatertankandthefuelfilter
infrontofthesolenoidvalve.Cleanthefiltersifnecessary.
Yearly, or after approx. 500 hours of operation:
-Desulphuriseanddecarbonizethecontinuous-flowheater.
-Changetheoil
Oil leakage: If oil leaks out, go to the nearest customer service
(dealer) immediately. (Environmental damages, transmission
damages)
In case of increased humidity or fluctuations in temperature
development of condensed water is possible; if the oil turns grey,
you must change it at once.
Care and Maintenance
The machine must be disconnected from the power supply when
servicing work is being carried out. The main switch should be in
position "0" and the plug out of the socket.