Tesy GCA 1015 K51 SRCM [5/60] In order to prevent injury to user and third persons in the event of faults in the hot water supply system the appliance must be mounted in premises outfitted with floor...

Tesy GCA 1520 SRC [5/60] In order to prevent injury to user and third persons in the event of faults in the hot water supply system the appliance must be mounted in premises outfitted with floor hydro insulation and sewer drainage don t place objects which are not waterproof under the appliance under any circumstances in the event of mounting the appliance in premises without floor hydro insulation a protective tank with a sewer discharge drainage must be placed under the appliance
Instructions for use and maintenance 5
EN
English
Dear Clients,
The TESY team would like to congratulate you on your new purchase.
We hope that your new appliance shall bring more comfort to your
home.
This technical description and instructions manual was prepared in
order to acquaint you with the product and the conditions of proper
installation and use. These instructions were also intended for use
by qualied technicians, who shall perform the initial installation, or
disassembly and repairs in the event of a breakdown.
The observance of the instructions contained herein is in the interest
of the buyer and represents one of the warranty conditions, outlined in
the warranty card.
The electric water heater complies with the requirements of
EN 60335-1, EN 60335-2-21.
I. PURPOSE OF USE
The appliance is designed to supply hot water to household facilities
equipped with a piping system operating with pressure not greater than
7 bars (0,7 Mpa).
The appliance is designed to function in closed, heated premises and is
not designed to operate at constant ow regime
.
II. TECHNICAL SPECIFICATIONS
1. Nominal volume V, liters - see the appliance's rating plate
2. Nominal voltage - see the appliance's rating plate
3. Nominal power consumption - see the appliance's rating plate
4. Nominal pressure - see the appliance's rating plate
5. Water heater type - closed accumulating water heater, with
thermal insulation
6. Inner coating: GC-glass-ceramics
III. DESCRIPTION AND PRINCIPLE OF OPERATION
The appliance consists of a body, ange, plastic control panel, safety
return valve.
1. The body consists of a steel reservoir (water tank) and plastic
housing (outer shell) with thermal insulation placed in-between,
and two pipes with thread G ½“, for cold water supply (marked with
a blue ring) and hot water discharge (marked with a red ring).The
inner reservoir is made of steel proved against corrosion by a special
glass-ceramic coating.
2. The ange is tted with electric heater and magnesium anode
protector. The ange is xed to the water tank with bolts.
The electric heater heats the water in the tank and is controlled by the
thermostat, which automatically maintains the preset temperature.
The plastic control panel incorporates: switch (depending on model),
adjustable thermostat (depending on model), and thermal cut-out and
control lamps.
The thermal cut-out is a device, which switches the heater o the
power supply when the water temperature reaches excessive values. If
this device is actuated, you should call a service station.
The signal lamps (depending on model) on the control panel indicate
the current mode of the unit.
The magnesium protector provides additional anti-corrosion protection
to the internal tank for heaters tted with glass-ceramic coating.
3. The safety-return valve prevents the appliance's complete
emptying in the event of cold water supply interruption. The valve
protects the appliance from pressure increases higher than the
allowed value(8 bar/0,8MPa) during heating (! pressure will increase
when temperature increases), by releasing the excess pressure
through the drain outlet. Water dropping out through the drains
during the warming process is a normal event that must be taken
into consideration when the boiler is installed.
The safety-return valve cannot protect the appliance from
water supply pressure exceeding the pressure indicated for
the appliance. In the event of higher water supply pressure there
will be constant leaks from the appliance drains.
IV. INSTALLATION AND SWITCH ON
Qualied technicians must perform all technical and
electrical assembly works. Certied technician is the person
who possesses the relevant competence in accordance with the
legislation of the respective country.
1. Installation
We recommend installation of the device at close proximity to locations
where hot water is used, in order to reduce heat losses during water
transportation. The selected location must exclude the possibility of
water spray originating from the showerhead or other water contacts.
The appliance is axed to a wall by means of mounting brackets
attached to the unit's body. Two hooks are used to x the appliance
(min. Ø 6 mm) rmly on the wall (included in the mounting set). The
bearing plank construction for boilers installed above / under sinks is
universal and allows the space between hooks to vary between 96 and
114mm. (g.1)
IMPORTANT: The type of boiler designed to be installed UNDER /
ABOVE a sink is marked on the appliance. Boilers designed for
installation above sinks are assembled in such a manner that the outlet/
inlet pipes are pointed downwards (to the oor of the premise). Boilers
designed for installation under sinks are assembled in such a manner
that the outlet/inlet pipes are pointed upwards (to the ceiling of the
premise).
For clear understanding of wall installation schemes, please refer to
g.2 (A above sink and B under sink).
In order to prevent injury to user and third persons in the
event of faults in the hot water supply system, the
appliance must be mounted in premises outtted with oor hydro
insulation and sewer drainage. Don't place objects, which are not
waterproof under the appliance under any circumstances. In the
event of mounting the appliance in premises without oor hydro
insulation, a protective tank with a sewer discharge drainage must
be placed under the appliance.
Notice: the set does not include a protective tank, it must be selected
by the client.