Ballu-Biemmedue GE 20 Инструкция по эксплуатации онлайн [13/26] 119745

Ballu-Biemmedue GE 20 Инструкция по эксплуатации онлайн [13/26] 119745
EN
13
Warning
Before any maintenance:
stop the heater following instruction “STOPPING
THE HEATER”;
unplug the heater;
wait until combustion chamber has been
completely cooled off.
Every 50 hours of operation: wash the filter with clean oil, or, if
very dirty, replace it, remove upper body parts and clean inside
and ventilator with compressed air, check correct attachment of
H.T. connectors to the electrodes and check H.T. cables, remove
burner assembly, clean and check electrode settings, adjust
according to Fig.2.