Suunto Vyper2 [18/55] Error conditions
![Suunto Vyper2 [18/55] Error conditions](/views2/1013553/page18/bg12.png)
Table 5.3. Oxygen alarms in NITROX mode
Alarm reasonAlarm type
Set oxygen partial pressure limit is exceeded. The
alternative display is replaced with a current blinking PO
2
value. You should immediately ascend above the PO
2
depth limit.
Continuous beeps for 3 minutes
and activated backlight
OLF value reaches 80%. The OLF value will start to
blink.
OLF value reaches 100%. The OLF value will blink.
NOTE
When the backlight is turned OFF, it does not illuminate when an
alarm is activated.
WARNING
WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE
MAXIMUM LIMIT IS REACHED, YOU MUST IMMEDIATELY ASCEND
UNTIL THE OLF VALUE STOPS BLINKING. Failure to take action
to reduce oxygen exposure after the warning is given can rapidly
increase the risk of oxygen toxicity, injury, or death.
5.6. Error conditions
The dive computer has warning indicators that alert you to react to certain situations that
would significantly increase the risk of DCI. If you do not respond to its warnings, the dive
computer will enter an Error mode, indicating that the risk of DCI has greatly increased.
If you understand the dive computer and operate it sensibly, it is very unlikely you will ever
put the instrument into the Error mode.
Omitted decompression
The Error mode results from omitted decompression, i.e. when you stay above the ceiling
for more than three minutes. During this three-minute period the Er warning is shown and
the audible alarm beeps. After this, the dive computer will enter a permanent Error mode.
The instrument will continue to function normally if you descend below the ceiling within
this three-minute period.
Once in the permanent Error mode, only the Er warning is shown in the center window.
The dive computer will not show times for ascent or stops. However, all the other displays
will function as before to provide information for ascent. You should immediately ascend
to a depth of 3 to 6 m/10 to 20 ft and remain at this depth until air supply limitations require
you to surface.
After surfacing, you should not dive for a minimum of 48 hours. During the permanent
Error mode, the Er text will be displayed in the center window and the planning mode will
be disabled.
5.7. DIVE mode settings
Suunto Vyper2 has several user-definable functions, as well as depth and time-related
alarms that you can set according to your personal preferences. The DIVE mode settings
are dependent on the dive sub-mode chosen (AIR, NITROX, GAUGE), so that, for example,
nitrox settings are only available in the DIVENitrox sub-mode.
The following figure shows how to enter the DIVE mode settings menu.
18
Содержание
- Table of contents 3
- Welcome to the world of suunto diving instruments 5
- Warnings cautions and notes 6
- Button symbols and functions 9
- Navigating in the menus 9
- Suunto vyper2 at a glance 9
- Getting started with your suunto vyper2 11
- Setting the alarm 11
- Setting the date 11
- Setting the time 11
- Time mode settings 11
- Ac water contacts 12
- Setting the backlight 12
- Setting the tones 12
- Setting the units 12
- Compass display 13
- Learning how to use your compass 13
- Tilt sensor 13
- Compass settings 14
- Declination 14
- Locking a bearing 14
- Calibration 15
- Before diving 16
- Dive computer limitations 16
- Emergency ascents 16
- The suunto rgbm deep stop algorithm 16
- Audible and visual alarms 17
- Nitrox 17
- Dive mode settings 18
- Error conditions 18
- Setting the depth alarm 19
- Setting the dive time alarm 19
- Setting the nitrox values 19
- Setting the personal altitude adjustments 20
- Setting the safety stops deep stops 20
- Setting the sample rate 20
- Accessing dive mode 21
- Activation and pre checks 21
- Dive mode activation 21
- Setting the rgbm values 21
- Battery power indication 22
- Diving at altitude 22
- Personal adjustments 23
- Mandatory safety stops 24
- Recommended safety stops 24
- Safety stops 24
- Deep stops 25
- Basic dive data 26
- Diving 26
- Diving in air mode diveair 26
- Ascent rate indicator 27
- Bookmark 27
- Decompression dives 27
- Safety stops 27
- Ceiling ceiling zone floor and decompression range 28
- Display above the ceiling 29
- Display above the floor 29
- Display at the ceiling zone 29
- Display below the floor 29
- Before diving in nitrox mode 30
- Default nitrox settings 30
- Diving in nitrox mode divenitrox 30
- Oxygen displays 30
- Gas change and multiple breathing gas mixes 31
- Oxygen limit fraction olf 31
- Diving in gauge mode divegauge 32
- After diving 33
- Dive numbering 33
- Repetitive dive planning 33
- Surface interval 33
- Dive planning mode plannodec 34
- Flying after diving 34
- Plan mode 34
- Dive numbering shown during dive planning 35
- Dive simulator 35
- Simulation mode plansimulator 35
- Dive logbook memlogbook 36
- Memory mode 36
- Dive history memhistory 37
- Suunto dive manager sdm 37
- Www suuntosports com and suunto diving world at www suunto com diving 38
- Care and maintenance 39
- Care of your dive computer 39
- Maintenance 39
- Water contacts and buttons 39
- Battery kit 40
- Battery replacement 40
- Battery replacement procedure 40
- Required tools 40
- Water resistance inspection 40
- Technical data 43
- Technical specifications 43
- Suunto rgbm adaptive decompression 44
- No decompression limits 45
- Altitude diving 46
- Oxygen exposure 46
- Copyright 47
- Intellectual property 47
- Patent notice 47
- Trademark 47
- After sales service 48
- Disclaimers 48
- Limits of liability and iso 9001 compliance 48
- User s responsibility 48
- Warranty 49
- Disposal of the device 50
- Glossary 51
- Two year warranty 54
Похожие устройства
- Yamaha DGX-620 Инструкция по эксплуатации
- D-Link DSL-G604T Инструкция по эксплуатации
- Patriot -Garden Т 5.0/400F PG Arizona Инструкция по эксплуатации
- Supra BSS-4000 Инструкция по эксплуатации
- LG DT-S585Y Инструкция по эксплуатации
- Suunto Vyper Air Инструкция по эксплуатации
- Yamaha DGX-630 Инструкция по эксплуатации
- Efco МZ 2060C GX160 Инструкция по эксплуатации
- D-Link DSL-2540/BRU Инструкция по эксплуатации
- Soehnle 65106 Инструкция по эксплуатации
- Elikor Сапфир 60 Инструкция по эксплуатации
- LG DT-S585NYG Инструкция по эксплуатации
- Suunto Vyper Инструкция по эксплуатации
- Texas LX550B 90045544 Инструкция по эксплуатации
- Yamaha EZ-150 Инструкция по эксплуатации
- D-Link DSL-510 Инструкция по эксплуатации
- LG DA-5620 Инструкция по эксплуатации
- Dekok UKA-1222 Инструкция по эксплуатации
- Zelmer 986.83 Инструкция по эксплуатации
- Suunto Stinger Инструкция по эксплуатации