Suunto Vyper2 [30/55] Before diving in nitrox mode
![Suunto Vyper2 [30/55] Before diving in nitrox mode](/views2/1013553/page30/bg1e.png)
DECOMPRESSION DIVE, ABOVE CEILING.
NOTE DOWNWARD POINTING ARROW, ER WARNING
AND ALARM. YOU SHOULD IMMEDIATLY (WITHIN
3 MINUTES) DES C END TO OR BELOW CEILING.
In addition, an Error warning (Er) reminds you that you have only three minutes to correct
the situation. You must immediately descend to, or below, the ceiling.
If you continue to violate the decompression, the dive computer will go into a permanent
Error Mode. In this mode, the instrument can only be used as a depth gauge and timer.
You must not dive again for at least 48 hours. (See Section 5.6. Error conditions).
6.2. Diving in NITROX mode (DIVEnitrox)
NITROX mode (DIVEnitrox) is the second dive mode available in Suunto Vyper2 and is
used when using oxygen- enriched gas mixtures.
6.2.1. Before diving in NITROX mode
If set to the NITROX mode, the correct oxygen percentage of the gas in your cylinder must
always be entered into the computer to ensure correct nitrogen and oxygen calculations.
The dive computer adjusts its mathematical nitrogen and oxygen calculation models
accordingly. The dive computer will not accept fractional percentage values of oxygen
concentration. Do not round up fractional percentages. For example, 31.8% oxygen should
be entered as 31%. Rounding up will cause nitrogen percentages to be understated and
will affect decompression calculations. If you want to adjust the computer to provide more
conservative calculations, use the personal adjustment feature to affect decompression
calculations, or reduce the PO
2
setting to affect oxygen exposure according to the entered
O
2
% and PO
2
values. Calculations based on nitrox use result in longer no-decompression
times and shallower maximum depths than diving with air.
As a safety precaution, the oxygen calculations in the computer are made with an oxygen
percentage of 1% + set O
2
% .
When the dive computer is set in NITROX mode, the Dive Planning mode calculates using
the O
2
% and PO
2
values that are currently in the computer.
To set the nitrox mixes, refer to Section 5.7.3. Setting the nitrox values.
Default nitrox settings
In NITROX mode, the Suunto Vyper2 allows you to set 1 or 2 nitrox mixes containing 21-
99% oxygen.
In the NITROX mode, the default setting for MIX1 is standard air (21% O
2
). It remains in
this setting until the O
2
% is adjusted to any other percentage of oxygen (22% - 99%). The
default setting for maximum oxygen partial pressure is 1.4 bar, however you are able to
set it in the range of 0.5 - 1.6 bar.
MIX2 is set to OFF by default. To set MIX2 , refer to Section 6.2.4. Gas change and multiple
breathing gas mixes. Oxygen percentages and maximum oxygen partial pressures for
MIX2 are stored permanently.
6.2.2. Oxygen displays
When NITROX mode is activated, the display will show the information in the figure below.
In NITROX mode, the maximum operational depth is calculated based on set O
2
% and
PO
2
values.
30
Содержание
- Table of contents 3
- Welcome to the world of suunto diving instruments 5
- Warnings cautions and notes 6
- Button symbols and functions 9
- Navigating in the menus 9
- Suunto vyper2 at a glance 9
- Getting started with your suunto vyper2 11
- Setting the alarm 11
- Setting the date 11
- Setting the time 11
- Time mode settings 11
- Ac water contacts 12
- Setting the backlight 12
- Setting the tones 12
- Setting the units 12
- Compass display 13
- Learning how to use your compass 13
- Tilt sensor 13
- Compass settings 14
- Declination 14
- Locking a bearing 14
- Calibration 15
- Before diving 16
- Dive computer limitations 16
- Emergency ascents 16
- The suunto rgbm deep stop algorithm 16
- Audible and visual alarms 17
- Nitrox 17
- Dive mode settings 18
- Error conditions 18
- Setting the depth alarm 19
- Setting the dive time alarm 19
- Setting the nitrox values 19
- Setting the personal altitude adjustments 20
- Setting the safety stops deep stops 20
- Setting the sample rate 20
- Accessing dive mode 21
- Activation and pre checks 21
- Dive mode activation 21
- Setting the rgbm values 21
- Battery power indication 22
- Diving at altitude 22
- Personal adjustments 23
- Mandatory safety stops 24
- Recommended safety stops 24
- Safety stops 24
- Deep stops 25
- Basic dive data 26
- Diving 26
- Diving in air mode diveair 26
- Ascent rate indicator 27
- Bookmark 27
- Decompression dives 27
- Safety stops 27
- Ceiling ceiling zone floor and decompression range 28
- Display above the ceiling 29
- Display above the floor 29
- Display at the ceiling zone 29
- Display below the floor 29
- Before diving in nitrox mode 30
- Default nitrox settings 30
- Diving in nitrox mode divenitrox 30
- Oxygen displays 30
- Gas change and multiple breathing gas mixes 31
- Oxygen limit fraction olf 31
- Diving in gauge mode divegauge 32
- After diving 33
- Dive numbering 33
- Repetitive dive planning 33
- Surface interval 33
- Dive planning mode plannodec 34
- Flying after diving 34
- Plan mode 34
- Dive numbering shown during dive planning 35
- Dive simulator 35
- Simulation mode plansimulator 35
- Dive logbook memlogbook 36
- Memory mode 36
- Dive history memhistory 37
- Suunto dive manager sdm 37
- Www suuntosports com and suunto diving world at www suunto com diving 38
- Care and maintenance 39
- Care of your dive computer 39
- Maintenance 39
- Water contacts and buttons 39
- Battery kit 40
- Battery replacement 40
- Battery replacement procedure 40
- Required tools 40
- Water resistance inspection 40
- Technical data 43
- Technical specifications 43
- Suunto rgbm adaptive decompression 44
- No decompression limits 45
- Altitude diving 46
- Oxygen exposure 46
- Copyright 47
- Intellectual property 47
- Patent notice 47
- Trademark 47
- After sales service 48
- Disclaimers 48
- Limits of liability and iso 9001 compliance 48
- User s responsibility 48
- Warranty 49
- Disposal of the device 50
- Glossary 51
- Two year warranty 54
Похожие устройства
- Yamaha DGX-620 Инструкция по эксплуатации
- D-Link DSL-G604T Инструкция по эксплуатации
- Patriot -Garden Т 5.0/400F PG Arizona Инструкция по эксплуатации
- Supra BSS-4000 Инструкция по эксплуатации
- LG DT-S585Y Инструкция по эксплуатации
- Suunto Vyper Air Инструкция по эксплуатации
- Yamaha DGX-630 Инструкция по эксплуатации
- Efco МZ 2060C GX160 Инструкция по эксплуатации
- D-Link DSL-2540/BRU Инструкция по эксплуатации
- Soehnle 65106 Инструкция по эксплуатации
- Elikor Сапфир 60 Инструкция по эксплуатации
- LG DT-S585NYG Инструкция по эксплуатации
- Suunto Vyper Инструкция по эксплуатации
- Texas LX550B 90045544 Инструкция по эксплуатации
- Yamaha EZ-150 Инструкция по эксплуатации
- D-Link DSL-510 Инструкция по эксплуатации
- LG DA-5620 Инструкция по эксплуатации
- Dekok UKA-1222 Инструкция по эксплуатации
- Zelmer 986.83 Инструкция по эксплуатации
- Suunto Stinger Инструкция по эксплуатации