Suunto Vyper2 [43/55] Technical data
9. TECHNICAL DATA
9.1. Technical specifications
Dimensions and weight:
• Diameter: 61.0 mm/2.4 in
• Thickness: 28 mm/1.1 in
• Weight: 68 g/2.4 oz
Depth gauge:
• Temperature compensated pressure sensor
• Salt water calibrated, in fresh water the readings are about 3% smaller (calibrated in
compliance with EN 13319)
• Maximum depth of operation: 100 m/328 ft (complying with EN 13319)
• Accuracy: ± 1% of full scale or better from 0 to 80 m/262 ft at 20°C/68°F (complying
with EN 13319)
• Depth display range: 0 to 150 m/492 ft
• Resolution: 0.1 m from 0 to 100 m/1 ft from 0 to 328 ft
Temperature display:
• Resolution: 1°C/1°F
• Display range: -20 to +50°C/-9 to +122°F
• Accuracy: ± 2°C/± 3.6°F within 20 minutes of temperature change
Calendar clock:
• Accuracy: ± 25 s/month (at 20°C/68°F)
• 12/24 h display
Displays only in NITROX mode:
• Oxygen %: 21 - 99
• Oxygen partial pressure display: 0.2 - 3.0 bar, depending on the limit setting
• Oxygen Limit Fraction: 1 - 200% with 1% resolution
Logbook/dive profile memory:
• Recording interval: 20 seconds adjustable (1,10,20,30,60s).
• Memory capacity: approximately 42 hours of diving with 20 second recording interval
• Depth accuracy: 0.3 m/1 ft
Operating conditions:
• Normal altitude range: 0 to 3,000 m/10,000 ft above sea level
• Operating temperature: 0°C to 40°C/32°F to 104°F
• Storage temperature: -20°C to +50°C/ -4°F to +122°F
It is recommended that the instrument be stored in a dry place at room temperature.
NOTE
Do not leave the dive computer in direct sunlight!
Tissue calculation model:
• Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke, BSc,
MSc, PhD)
• 9 tissue compartments
• Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes (on
gassing). The off gassing halftimes are slowed down
• Reduced gradient (variable) "M" values based on diving habit and dive violations. The
"M" values are tracked up to 100 hours after a dive
• The EAN and oxygen exposure calculations are based on recommendations by R.W.
Hamilton, PhD and currently accepted exposure time limit tables and principles
Battery:
• One 3 V lithium battery: CR 2450
• Battery storage time (shelf life): Up to three years
• Replacement: Every three years, or more often depending on dive activity
43
Содержание
- Table of contents 3
- Welcome to the world of suunto diving instruments 5
- Warnings cautions and notes 6
- Button symbols and functions 9
- Navigating in the menus 9
- Suunto vyper2 at a glance 9
- Getting started with your suunto vyper2 11
- Setting the alarm 11
- Setting the date 11
- Setting the time 11
- Time mode settings 11
- Ac water contacts 12
- Setting the backlight 12
- Setting the tones 12
- Setting the units 12
- Compass display 13
- Learning how to use your compass 13
- Tilt sensor 13
- Compass settings 14
- Declination 14
- Locking a bearing 14
- Calibration 15
- Before diving 16
- Dive computer limitations 16
- Emergency ascents 16
- The suunto rgbm deep stop algorithm 16
- Audible and visual alarms 17
- Nitrox 17
- Dive mode settings 18
- Error conditions 18
- Setting the depth alarm 19
- Setting the dive time alarm 19
- Setting the nitrox values 19
- Setting the personal altitude adjustments 20
- Setting the safety stops deep stops 20
- Setting the sample rate 20
- Accessing dive mode 21
- Activation and pre checks 21
- Dive mode activation 21
- Setting the rgbm values 21
- Battery power indication 22
- Diving at altitude 22
- Personal adjustments 23
- Mandatory safety stops 24
- Recommended safety stops 24
- Safety stops 24
- Deep stops 25
- Basic dive data 26
- Diving 26
- Diving in air mode diveair 26
- Ascent rate indicator 27
- Bookmark 27
- Decompression dives 27
- Safety stops 27
- Ceiling ceiling zone floor and decompression range 28
- Display above the ceiling 29
- Display above the floor 29
- Display at the ceiling zone 29
- Display below the floor 29
- Before diving in nitrox mode 30
- Default nitrox settings 30
- Diving in nitrox mode divenitrox 30
- Oxygen displays 30
- Gas change and multiple breathing gas mixes 31
- Oxygen limit fraction olf 31
- Diving in gauge mode divegauge 32
- After diving 33
- Dive numbering 33
- Repetitive dive planning 33
- Surface interval 33
- Dive planning mode plannodec 34
- Flying after diving 34
- Plan mode 34
- Dive numbering shown during dive planning 35
- Dive simulator 35
- Simulation mode plansimulator 35
- Dive logbook memlogbook 36
- Memory mode 36
- Dive history memhistory 37
- Suunto dive manager sdm 37
- Www suuntosports com and suunto diving world at www suunto com diving 38
- Care and maintenance 39
- Care of your dive computer 39
- Maintenance 39
- Water contacts and buttons 39
- Battery kit 40
- Battery replacement 40
- Battery replacement procedure 40
- Required tools 40
- Water resistance inspection 40
- Technical data 43
- Technical specifications 43
- Suunto rgbm adaptive decompression 44
- No decompression limits 45
- Altitude diving 46
- Oxygen exposure 46
- Copyright 47
- Intellectual property 47
- Patent notice 47
- Trademark 47
- After sales service 48
- Disclaimers 48
- Limits of liability and iso 9001 compliance 48
- User s responsibility 48
- Warranty 49
- Disposal of the device 50
- Glossary 51
- Two year warranty 54
Похожие устройства
- Yamaha DGX-620 Инструкция по эксплуатации
- D-Link DSL-G604T Инструкция по эксплуатации
- Patriot -Garden Т 5.0/400F PG Arizona Инструкция по эксплуатации
- Supra BSS-4000 Инструкция по эксплуатации
- LG DT-S585Y Инструкция по эксплуатации
- Suunto Vyper Air Инструкция по эксплуатации
- Yamaha DGX-630 Инструкция по эксплуатации
- Efco МZ 2060C GX160 Инструкция по эксплуатации
- D-Link DSL-2540/BRU Инструкция по эксплуатации
- Soehnle 65106 Инструкция по эксплуатации
- Elikor Сапфир 60 Инструкция по эксплуатации
- LG DT-S585NYG Инструкция по эксплуатации
- Suunto Vyper Инструкция по эксплуатации
- Texas LX550B 90045544 Инструкция по эксплуатации
- Yamaha EZ-150 Инструкция по эксплуатации
- D-Link DSL-510 Инструкция по эксплуатации
- LG DA-5620 Инструкция по эксплуатации
- Dekok UKA-1222 Инструкция по эксплуатации
- Zelmer 986.83 Инструкция по эксплуатации
- Suunto Stinger Инструкция по эксплуатации