Suunto Vyper2 [29/55] Display above the ceiling
![Suunto Vyper2 [29/55] Display above the ceiling](/views2/1013553/page29/bg1d.png)
WARNING
NEVER ASCEND ABOVE THE CEILING! You must not ascend above
the ceiling during your decompression. In order to avoid doing so by
accident, you should stay somewhat below the ceiling.
Display below the floor
The blinking ASC TIME and an upward pointing arrow indicate that you are below the
floor. You should start your ascent immediately. The ceiling depth is shown on the left
side, and the minimum total ascent time on the right side, of the center window. Below is
an example of a decompression dive without Deep Stops, below the floor.
UPWARD POINTING ARROW, BLINKING ASC
TIME AND AN ALARM TELL YOU TO ASCEND. MINIMUM
TOTAL ASCENT TIME INCLUDING MANDATORY SAFETY
STOP IS 15 MINUTES. CEILING IS AT 3 M.
Display above the floor
When you ascend above the floor, the ASC TIME display stops blinking and the upward
pointing arrow disappears. Below is an example of a decompression dive above the floor.
UPWARD POINTING ARROW HAS
DISAPPEARED AND ASC TIME LABEL HAS
STOPPED BLINKING, MEANING YOU ARE IN
THE DECOMPRESSION RANGE.
Decompression will now begin, but is very slow. You should therefore continue your ascent.
Display at the ceiling zone
When you reach the ceiling zone, the display will show you two arrows pointing at each
other (the “hour glass” icon). Below is an example of a decompression dive at the ceiling
zone.
TWO ARROWS POINT AT EACH OTHER
“HOUR GLASS”. YOU ARE IN THE OPTIMUM CEILING
ZONE AT 3 M. AND YOUR MINIMUM ASCENT TIME IS
15 MINUTES.
During the decompression stop, ASC TIME will count down towards zero. When the ceiling
moves upwards, you can ascend to the new ceiling. You may surface only after the ASC
TIME and CEILING labels have disappeared, which means that the decompression stop
and any Mandatory Safety Stop have been completed. You are advised, however, to stay
until the STOP sign has also disappeared. This indicates that the three minute
Recommended Safety Stop has also been completed.
Display above the ceiling
If you ascend above the ceiling during a decompression stop, a downward pointing arrow
will appear and a continuous beeping starts.
29
Содержание
- Table of contents 3
- Welcome to the world of suunto diving instruments 5
- Warnings cautions and notes 6
- Button symbols and functions 9
- Navigating in the menus 9
- Suunto vyper2 at a glance 9
- Getting started with your suunto vyper2 11
- Setting the alarm 11
- Setting the date 11
- Setting the time 11
- Time mode settings 11
- Ac water contacts 12
- Setting the backlight 12
- Setting the tones 12
- Setting the units 12
- Compass display 13
- Learning how to use your compass 13
- Tilt sensor 13
- Compass settings 14
- Declination 14
- Locking a bearing 14
- Calibration 15
- Before diving 16
- Dive computer limitations 16
- Emergency ascents 16
- The suunto rgbm deep stop algorithm 16
- Audible and visual alarms 17
- Nitrox 17
- Dive mode settings 18
- Error conditions 18
- Setting the depth alarm 19
- Setting the dive time alarm 19
- Setting the nitrox values 19
- Setting the personal altitude adjustments 20
- Setting the safety stops deep stops 20
- Setting the sample rate 20
- Accessing dive mode 21
- Activation and pre checks 21
- Dive mode activation 21
- Setting the rgbm values 21
- Battery power indication 22
- Diving at altitude 22
- Personal adjustments 23
- Mandatory safety stops 24
- Recommended safety stops 24
- Safety stops 24
- Deep stops 25
- Basic dive data 26
- Diving 26
- Diving in air mode diveair 26
- Ascent rate indicator 27
- Bookmark 27
- Decompression dives 27
- Safety stops 27
- Ceiling ceiling zone floor and decompression range 28
- Display above the ceiling 29
- Display above the floor 29
- Display at the ceiling zone 29
- Display below the floor 29
- Before diving in nitrox mode 30
- Default nitrox settings 30
- Diving in nitrox mode divenitrox 30
- Oxygen displays 30
- Gas change and multiple breathing gas mixes 31
- Oxygen limit fraction olf 31
- Diving in gauge mode divegauge 32
- After diving 33
- Dive numbering 33
- Repetitive dive planning 33
- Surface interval 33
- Dive planning mode plannodec 34
- Flying after diving 34
- Plan mode 34
- Dive numbering shown during dive planning 35
- Dive simulator 35
- Simulation mode plansimulator 35
- Dive logbook memlogbook 36
- Memory mode 36
- Dive history memhistory 37
- Suunto dive manager sdm 37
- Www suuntosports com and suunto diving world at www suunto com diving 38
- Care and maintenance 39
- Care of your dive computer 39
- Maintenance 39
- Water contacts and buttons 39
- Battery kit 40
- Battery replacement 40
- Battery replacement procedure 40
- Required tools 40
- Water resistance inspection 40
- Technical data 43
- Technical specifications 43
- Suunto rgbm adaptive decompression 44
- No decompression limits 45
- Altitude diving 46
- Oxygen exposure 46
- Copyright 47
- Intellectual property 47
- Patent notice 47
- Trademark 47
- After sales service 48
- Disclaimers 48
- Limits of liability and iso 9001 compliance 48
- User s responsibility 48
- Warranty 49
- Disposal of the device 50
- Glossary 51
- Two year warranty 54
Похожие устройства
- Yamaha DGX-620 Инструкция по эксплуатации
- D-Link DSL-G604T Инструкция по эксплуатации
- Patriot -Garden Т 5.0/400F PG Arizona Инструкция по эксплуатации
- Supra BSS-4000 Инструкция по эксплуатации
- LG DT-S585Y Инструкция по эксплуатации
- Suunto Vyper Air Инструкция по эксплуатации
- Yamaha DGX-630 Инструкция по эксплуатации
- Efco МZ 2060C GX160 Инструкция по эксплуатации
- D-Link DSL-2540/BRU Инструкция по эксплуатации
- Soehnle 65106 Инструкция по эксплуатации
- Elikor Сапфир 60 Инструкция по эксплуатации
- LG DT-S585NYG Инструкция по эксплуатации
- Suunto Vyper Инструкция по эксплуатации
- Texas LX550B 90045544 Инструкция по эксплуатации
- Yamaha EZ-150 Инструкция по эксплуатации
- D-Link DSL-510 Инструкция по эксплуатации
- LG DA-5620 Инструкция по эксплуатации
- Dekok UKA-1222 Инструкция по эксплуатации
- Zelmer 986.83 Инструкция по эксплуатации
- Suunto Stinger Инструкция по эксплуатации