Braun ts 775 [11/80] G cleaning the anticalc valve

Braun TS775TP TexStyle 7 [11/80] G cleaning the anticalc valve
11
other chemicals. To clean the soft material
on the handle, use soapy water.
G Cleaning the anticalc valve
The anticalc valve located on the lower
end of the steam regulator has to be
decalcifi ed regularly (e.g. whenever steam
development is insuffi cient). For this, the
water tank has to be empty.
Removing the steam regulator with the
anticalc valve
Turn the steam regulator clockwise
towards the steam setting «6». Keep
on turning fi rmly beyond the resistance
until the steam regulator is lifted. When
positioned at x, pull it out vertically.
Do not touch the anticalc valve at its lower
end. Immerse the anticalc valve in vinegar
(not vinegar essence) or lemon juice for
a minimum of 30 minutes. Brush off
remaining residues and rinse under
running water (fi g. H, 1-7).
Re-inserting the steam regulator
When re-inserting the steam regulator,
make sure the steam regulator base still
points on setting x (fi g. H, 8). Firmly push
down the steam regulator until it turns
back to setting «6» (fi g. H) where it
catches.
Notice: The iron must never be used
without steam regulator.
H Decalcifying/anticalc system
In order to clean the steam chamber from
residues, decalcify it as shown in picture
section I, 1-8.
Caution: Hot water and steam will come
out from the sole plate when the steam
regulator is turned clockwise beyond
setting «6».
Wait for the sole plate to cool down, then
clean it as described above. Then refi ll the
tank with water, heat up the iron and press
the precision shot button 4 times to rinse
the iron before ironing (fi g. I, 9-13).
Do not use commercial decalcifi ers, they
may damage the iron.
Trouble-shooting guide
Problem Remedy
Drops coming
out of the steam
vents.
Turn the steam
regulator anti-clock-
wise to reduce the
steam or turn it off.
Take longer intervals
when pressing the
precision shot button.
Select a higher
temperature setting.
Less steam
develops or no
steam at all.
Check water level.
Clean the anticalc
valve.
Calcium particles
coming through
the steam vents.
Decalcify the steam
chamber.
Subject to change without notice.
Please do not dispose of the product
in the household waste at the end of its
useful life. Disposal can take place at a
Braun Service Centre or at appropriate
collection points provided in your country.
5712710054_TS_780-755_S06-80.indd 115712710054_TS_780-755_S06-80.indd 11 07.05.13 09:0207.05.13 09:02

Содержание

other chemicals To clean the soft material on the handle use soapy water G Cleaning the anticalc valve The anticalc valve located on the lower end of the steam regulator has to be decalcified regularly e g whenever steam development is insufficient For this the water tank has to be empty Removing the steam regulator with the anticalc valve Turn the steam regulator clockwise towards the steam setting 6 Keep on turning firmly beyond the resistance until the steam regulator is lifted When positioned at pull tout vertically Do not touch the anticalc valve at its lower end Immerse the anticalc valve in vinegar not vinegar essence or lemon juice for a minimum of 30 minutes Brush off remaining residues and rinse under running water fig H 1 7 Re inserting the steam regulator When re inserting the steam regulator make sure the steam regulator base still points on setting fig H 8 Firmly push down the steam regulator until it turns back to setting 6 fig H where it catches Notice The iron must never be used without steam regulator Trouble shooting guide Problem Remedy Drops coming out of the steam vents Turn the steam regulator anti clockwise to reduce the steam or turn it off Take longer intervals when pressing the precision shot button Select a higher temperature setting Less steam develops or no steam at all Check water level Clean the anticalc valve Calcium particles coming through the steam vents Decalcify the steam chamber Subject to change without notice Please do not dispose of the product in the household waste at the end of its useful life Disposal can take place at a Braun Service Centre or at appropriate collection points provided in your country H Decalcifying anticalc system In order to clean the steam chamber from residues decalcify it as shown in picture section 1 1 8 Caution Hot water and steam will come out from the sole plate when the steam regulator is turned clockwise beyond setting 6 Wait for the sole plate to cool down then clean it as described above Then refill the tank with water heat up the iron and press the precision shot button 4 times to rinse the iron before ironing fig 1 9 13 Do not use commercial decalcifiers they may damage the iron 11 5712710054_TS_780 755_S06 80 indd 11 07 05 13 09 02