Gorenje gt 15 u/v6 [19/72] Operation and maintenance

Gorenje gt 15 u/v6 [19/72] Operation and maintenance
19
GB
Legend:
1 - Thermostat
2 - Thermal fuse
3 - Heating element
4 - Light indicator
5 - Connector
L- Phase lead
N- Neutral lead
- Earth lead
Electrical installation drawing
OPERATION AND MAINTENANCE
The water heater is ready for use once it has been connected to water and power. By turning the
thermostat knob on the front side of the protective cover, water temperature can be set between
25 °C, position
and 75 °C, position “ “. We recommend that the knob be set to position
“ as this ensures the most economic operation of the water heater.
This way the water temperature is maintained at 55 °C. The operation of the heater at this
temperature level also results in reduced build-up of calcium and lime, as well as reduced heat
loss than is the case at higher temperatures. Due to safety reasons you can optionally set the
highest temperature value of water in the heater. Proceed as follows:
a) Insert screwdriver in slot 1 and remove button cover
2,
b) Set knob limiter 3 to any desired temperature value,
C- 35 °C
B- 45 °C
A- 55 °C
O- 75 °C
c) Replace knob cover 2 to the knob.
The operation of the heating element is indicated by the
light indicator that stays on until the temperature in the
tank has reached the set level or until the heater has
been deliberately switched off. When the water heater
is not in use for longer periods of time, it should be
protected from freezing by setting the temperature to
“. Do not disconnect the power. Thus the temperature of the water in the tank is maintained at
about 9 °C. Should you choose to disconnect the power, the water heater should be thoroughly
drained before the onset of freezing conditions. The exterior of the water heater may be cleaned
with a mild detergent solution. Do not use solvents and abrasive cleaners.
Regular preventive maintenance inspections ensure faultless performance and long life of your
heater. The first of these inspections should be carried out by the authorised maintenance service
provider about two years from the date of installation in order to check the wear of the protective
anticorrosion anode and remove any build-up of calcium and lime as required. The build-up of
calcium and lime in the water heater depends on the quality, quantity and temperature of water
flowing through the heater. The maintenance service provider shall also issue a condition report
and recommend the approximate date of the next inspection.
In the event of the heater breaking down, you are kindly requested to contact the authorised
maintenance service provider located closest to you. Please do not attempt to carry out
any repairs yourself.