Chapter 5: Chassis Setup and Maintenance
5-8 Checking the Airow in the System
Proper airow allows the chassis to keep the server components cooled and prevent
damage. Use the following steps to check the airow after setting up the system
or servicing.
Checking the Server's Air Flow
Make sure that no cables or foreign objects obstruct airow through the 1.
chassis. Pull all excess cabling out of the airow path or use shorter cables.
For the SC523 chassis, it is recommended that cables run beside the power
supply as much as possible.
Make sure there are no objects to obstruct airow in and out of the server. 2.
Do not operate the server without hard drives or dummy drives in the hard 3.
drive trays.
Use recommended server parts only.4.
The control panel LEDs inform you of system status. See the System Interface sec-
tion of this manual for details on the LEDs and the control panel buttons.
Once the air shroud has been properly installed, do the following:
Install the DVD-ROM drive unit and connect the DVD-ROM drive to the moth-1.
erboard.
Install the hard drive tray. 2.
Securely close the chassis cover.3.
Installation Complete
This completes the setup and conguration of the system. The system fans and
power supply are pre-installed in the chassis. In the unlikely event that you need
to replace the system fans or power supply, proceed to the following sections. If
the chassis will be installed into a rack, proceed to the next chapter for rack instal-
lation instructions.