CONEL SPECTRE v3 ERT — настройка функций расширения и мониторинга на маршрутизаторе [86/136]

Превью страниц Страница 86 / 136
CONEL SPECTRE v3 ERT [86/136] Configuration
4. CONFIGURATION
Activating the Enable I/O extension function allows you monitor the binary I/O inputs on
the router.
Selecting Enable M-BUS extension and entering the Baudrate, Parity and Stop Bits lets
you monitor the meter status connected to the expansion port MBUS status.
Selecting Enable reporting to supervisory system and entering the IP Address and Period
lets you send statistical information to the monitoring system, R-SeeNet.
Item Description
IP Address IP address
Period Period of sending statistical information (in minutes).
Table 53: SNMP Configuration (R-SeeNet)
Each monitored value is uniquely identified using a numerical identifier OID Object Iden-
tifier. This identifier consists of a progression of numbers separated by a point. The shape
of each OID is determined by the identifier value of the parent element and then this value is
complemented by a point and current number. So it is obvious that there is a tree structure.
The following figure displays the basic tree structure that is used for creating the OIDs.
Figure 50: OID Basic Structure
The SNMP values that are specific for Conel routers create the tree starting at OID =
.1.3.6.1.4.1.30140. You interpret the OID in the following manner:
iso.org.dod.internet.private.enterprises.conel
77

Содержание

233