Administrators Guide for SIP-T2 Series/T19(P) E2/T4 Series IP Phones
722
The system log level is set as 6, the informational level.
Note
To configure the phone to export the system log to a syslog server via web user
interface:
1. Click on Settings->Configuration.
2. Mark the Server radio box in the Export System Log field.
3. Enter the IP address or domain name of the syslog server in the Server Name field.
4. Click Confirm to accept the change.
A dialog box pops up to prompt Do you want to restart your machine?. The
configuration will take effect after a reboot.
5. Click OK to reboot the phone.
The system log will be exported successfully to the desired syslog server after a
reboot.
6. Reproduce the issue.
To export a log file to the local system via web user interface:
1. Click on Settings->Configuration.
2. Mark the Local radio box in the Export System Log field.
3. Reproduce the issue.
Informational level may make some sensitive information accessible (e.g., password
dial number), we recommend that you reset the system log level to 3 after providing the
syslog file.