Installation
308687J 5
Grounding
Pump: follow the manufacturer’s recommendations.
Air and fluid hoses: use only grounded hoses.
Air compressor: follow manufacturers recommenda-
tions.
Fluid supply container: follow local code.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the dispense
valve firmly to the side of a grounded metal pail, then
trigger the valve.
Factory Settings
The meter is factory calibrated for 10W-30 oil, and the
default unit of measurement is quarts. For other fluids
and different units of measurement, see Changing the
Measurement Units and Calibration Factor on page 8.
The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.