Graco IM5 239824 [9/14] Battery replacement procedure

Graco IM5 239824 [9/14] Battery replacement procedure
Service
308687J 9
Battery Replacement Procedure
(F
IG. 5)
1. Relieve Pressure, (see procedure in previous sec-
tion).
2. Remove the four screws (3) holding the electronic
control (1) and metering unit (4) together.
3. Remove the battery.
4. Install the new battery.
NOTE: See Technical Data, page X for recommended
batteries.
5. Install the electronic control to the metering unit (4),
aligning the longer screws boss on the meter hous-
ing with the counter bore in the plastic housing.
6. Install the four screws (3) holding the electronic con-
trol (1) to the metering unit (4) together. Torque the
screws to 15-20 in-lb (1.7 to 2.3 N•m) or until no gap
exists between the electronic control and the meter-
ing unit.
Electronic Control Replacement
Procedure (F
IG. 6)
1. Relieve Pressure, (see procedure in previous sec-
tion).
2. Remove the four screws (3) holding the electronic
control (1) and metering unit (4) together.
3. Remove the battery. (See Battery Replacement Pro-
cedure in the previous section).
FIG. 5
NOTICE
To avoid pinching the battery wires, install the bat-
tery as shown in F
IG. 5. The battery wire should
extend to the far side of the battery compartment.
NOTICE
Closing the gap between the electronic control and
the metering unit is very important; it ensures that
no moisture can enter the electronics.
FIG. 6
Скачать