Problem Cause Solution
Battery icon is shown on the display Battery is low Replace the battery. See Battery
Replacement Procedure, page 9
and Technical Data, page 13 for rec-
ommended battery.
Digital display does not activate Battery is low Replace the battery. See Battery
Replacement Procedure, page 9
and Technical Data, page 13 for rec-
ommended battery.
Electronic control is malfunctioning Replace electronic control. See Elec-
tronic Control Replacement Proce-
dure, page 9.
There is no fluid flow Metering unit is malfunctioning Replace the meter.
Strainer (if used) is clogged Remove and clean or replace strainer
using Strainer Kit 239876. See
Accessories, page 12.
Pump is not turned on. Turn on pump.