Graco 24F878 [8/14] Mounting bracket 2 installation
Installation
8 3A1189G
The suction line is designed to allow for full evacuation
of the container so it will bend slightly when installed.
1. Connect suction tube (6c) to drum insert (6b) to
pump.
2. Insert suction line (6c) into drum.
3. Install drum coupler (6a) into drum insert (6b)
4. Connect hose (E) to pump fitting. Use a flat-blade
screw driver to tighten hose clamp (F).
5. Connect the air supply line (C) to the air controls.
Nozzle (3) Installation: Models 24F878 and
24F947
Numerals used in the following instructions refer to ref-
erence numbers used in the Parts Lists provided on
pages 10 - 11.
Wall Mount Model: 24F878
1. Install hose (9) into back of nozzle (3). Wrench
tighten.
2. Install other end of hose (9) into pump outlet fitting.
Drum Mount Model: 24F947
1. Install clamp over end of fluid supply hose (9).
2. Push end of fluid supply hose (9) over end of nozzle
(3) fitting.
3. Position clamp over fitting and hose end. Use a flat
blade screw driver to tighten screw and secure
clamp to the end of hose over barbed fitting.
4. Install other end of hose (9) into pump outlet fitting.
Meter (10) Installation: Models 24F531 and
24M499
Uses Meter Kit 24H293 that includes the following parts:
-Meter (10a), Swivel (10b), Fitting (10c) and Seal (10d)
and Fitting (10e).
1. Install hose (9) into back of nozzle (3). Wrench
tighten.
2. Install pipe swivel fitting (10b) into pump outlet.
Wrench tighten.
3. Install fitting (10c) into swivel (10b). Wrench tighten.
4. Install meter (10a) to fitting (10c). Wrench tighten.
5. Install fitting (10e) into meter. Wrench tighten.
6. Install hose (9) into fitting (10e).
Mounting Bracket (2) Installation
• When installing bracket, be sure the mounting sur-
face can support the weight of the pump, hoses and
all accessories, as well as the stress caused during
operation.
• On all installations mount the pump using screws
and nuts provided.
• Always keep nozzle bath tray filled with water.
Wall Mounting Kit 24F870 (2): Models 24F531 and
24F878 only
Wall mounted DEF System Models 24F531 and 24F878
include a Mounting Bracket Kit containing the following
parts - Screws (2a), Screws (2b), Washers (2c), Plain
Washers (2d), Hex Nuts (2e), Mounting Plate (2f), Noz-
zle Bath Holder (2g), Nozzle Holder Bracket (2h) and
screws (2j). The Mounting Bracket and Nozzle Holder
are also identified as items J and M on the Typical
Installation Diagram provided on page 4.
1. Determine location to install mounting plate (2f).
2. Use holes the plate (2f) as a template. Mark mount-
ing hole locations. Use a drill to predrill mounting
holes in mounting surface.
3. Use screws (2a) (provided) to install plate (2f).
4. Align holes in nozzle holder bracket (2h) with holes
in plate (2f). Use screws (2b), nuts (2e) and wash-
ers (2d)(provided) to install meter tray plate.
5. Place nozzle bath (2g) in nozzle holder bracket (2h).
Fill bath with water. Keep meter bath filled with
water at all times.
Содержание
- A1189g 1
- Diesel exhaust fluid def system 1
- For pumping diesel exhaust fluid not approved for use in european explosive atmosphere locations for professional use only 1
- Important safety instructions 1
- Instructions 1
- Model no 24f531 1
- Model no 24f878 1
- Model no 24f947 1
- Model no 24m499 1
- Related manuals 1
- Warning 2
- Warnings 2
- Warning 3
- Installation 4
- Model 24f531 wall mounted with meter model 24f878 wall mounted no meter 4
- Typical installations 4
- Model 24f947 5
- Model 24f947 drum mounted without meter model 24m499 drum mounted with meter 5
- Model 24m499 5
- General installation information 6
- Identification label for ce mark 6
- Installation date 6
- Meter 10 installation models 24f531 and 24m499 8
- Mounting bracket 2 installation 8
- Nozzle 3 installation models 24f878 and 24f947 8
- Flushing 9
- Operation 9
- Priming 9
- Wall mounted with meter model 24f531 wall mounted without meter model 24f878 10
- Drum mounted without meter model 24f947 drum mounted with meter model 24m499 11
- A screw cap hex head 4 2b screw thumb 1 4 20 x 2 2 2d washer plain 12 2e nut hex 6 2f plate pump mount 1 2g holder nozzle bath 1 2h bracket nozzle holder 1 2j screw hh 1 4 x 20 x 0 5 not shown 2 12
- A screw cap hex head not shown 4 2b screw cap hex head 4 2c washer not shown 4 2d washer plain 14 2e nut hex 7 2f plate pump mount 1 2g holder nozzle bath 1 2h bracket nozzle holder 1 2j screw hh 1 4 x 20 x 0 5 not shown 3 12
- Bracket 2 kits 12
- Bracket 24f870 models 24f531 24f878 2 bracket 24f679 model 24f947 24m499 12
- Technical data 12
- Us metric 12
- Us metric 13
- Copyright 2011 graco inc is registered to iso 9001 www graco com february 2011 revised june 2014 14
- Graco headquarters minneapolis international offices belgium china japan korea 14
- Graco inc p o box 1441 minneapolis mn 55440 1441 14
- Graco information 14
- Graco standard warranty 14
- To place an order contact your graco distributor or call to identify the nearest distributor phone 612 623 6928 or toll free 1 800 533 9655 fax 612 378 3590 14
Похожие устройства
- Graco 24F878 Технические характеристики
- Graco 24F947 Инструкция по эксплуатации
- Graco 24F947 Технические характеристики
- Graco 24M499 Инструкция по эксплуатации
- Graco 24M499 Технические характеристики
- Graco Python XL 1/4" Инструкция по эксплуатации
- Graco Python XL 1/4" Технические характеристики
- Graco Python XL 3/8" Инструкция по эксплуатации
- Graco Python XL 3/8" Технические характеристики
- Graco Python XL 1/2" Инструкция по эксплуатации
- Graco Python XL 1/2" Технические характеристики
- Graco Python XL 5/8" Инструкция по эксплуатации
- Graco Python XL 5/8" Технические характеристики
- Graco Python XL 3/4" Инструкция по эксплуатации
- Graco Python XL 3/4" Технические характеристики
- Graco Python 1/8" Инструкция по эксплуатации
- Graco Python 1/8" Брошюра
- Graco Python 3/16" Инструкция по эксплуатации
- Graco Python 3/16" Технические характеристики
- Graco Python 1/4" Инструкция по эксплуатации