Moxa TN-5510A-8PoE-2GLSX-ODC-WV-CT-T [17/20] Led indicators

Moxa TN-5510A-2GTXBP-WV-CT-T [17/20] Led indicators
- 17 -
With the maximum segment length of category 5 twisted-pair cable being
100 meters, cable length must be considered when designing a network
that utilizes this function. For example, the total length of the cables from
Switch A to B and from B to C must be no more than 100 meters. This way,
if the two adjacent nodes (switch B and C for example) encounter a power
failure, there will be no stoppage, provided that the total length of the
cables A-to-B, B-to-C, and C-to-D are no more than 100 meters.
The bypass relay function works best for networks with linear topologies.
ToughNet™ switches with bypass relay function are not recommended to
be used in networks that employ ring topologies because network loops
may occur when redundancy protocols such as RSTP or TurboRing™ are
applied.
LED Indicators
Several LED indicators are located on the ToughNet switch’s front panel.
The function of each LED is described in the table below.
LED
Color
State
Description
System LEDs
PWR1
AMBER
ON
Power is being supplied to power input
PWR1.
OFF
Power is not being supplied to power
input PWR1
PWR2
AMBER
ON
Power is being supplied to power input
PWR2.
OFF
Power is not being supplied to power
input PWR2.
FAULT
RED
ON
When the corresponding PORT alarm is
enabled, and a user-configured event is
triggered.
OFF
When the corresponding PORT alarm is
enabled and a user-configured event is
not triggered, or when the corresponding
PORT alarm is disabled.
MSTR/
HEAD
GREEN
ON
When the TN switch is either the Master
of this Turbo Ring, or the Head of this
Turbo Chain.
Blinking
When the TN switch is Ring Master of this
Turbo Ring and the Turbo Ring is broken,
or it is Chain Head of this Turbo Chain
and the Turbo Chain is broken.
OFF
When the TN switch is neither the Master
of this Turbo Ring, nor the Head of this
Turbo Chain.
Bypassing
Switch B
Switch C
Switch D

Похожие устройства

Скачать