Moxa UC-8112-LX-CG [6/23] Serial interface
![Moxa UC-8112-LX-CG [6/23] Serial interface](/views2/1199683/page6/bg6.png)
UC-8112-ME-T Series Introduction
1-3
Hardware Specifications
Computer
CPU:
ARMv7 Cortex-A8 300/600/1000 MHz
USB:
USB 2.0 host x 1 (type A connector)
DRAM:
UC
-8112-ME-T-LX: 512 MB DDR3 SDRAM
UC
-8112-ME-T-LX-US: 512 MB DDR3 SDRAM
OS (pre
-installed): Debian ARM 7 (Kernel 3.2)
Storage
Storage
Expansion:
• SDHC/SDXC socket for storing OS and storage expansion
•
4 GB eMMC flash with OS pre-installed
Ethernet Interface
LAN:
2 auto-sensing 10/100 Mbps ports (RJ45)
Magnetic Isolation Protection:
1.5 kV built-in
Serial Interface
Serial
Standards: 2 RS-232/422/485 ports, software-selectable (5-pin terminal block connector)
Console Port:
RS-232 (TxD, RxD, GND), 4-pin pin header output (115200, n, 8, 1)
Serial Communication Parameters
Data Bits:
5, 6, 7, 8
Stop Bits:
1, 1.5, 2
Parity:
None, Even, Odd, Space, Mark
Flow Control:
XON/XOFF, ADDC® (automatic data direction control) for RS-485
Baudrate:
Max. 921600 bps
Serial Signals
RS
-232: TxD, RxD, RTS, CTS, GND
RS
-422: TxD+, TxD-, RxD+, RxD-, GND
RS
-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS
-485-2w: Data+, Data-, GND
LEDs
System:
Power x 1, USB x 1, SD x 1, signal strength x 3-+
LAN:
10M/100M on connector
Programmable:
Diagnosis x 3
Switches and Buttons
Push Button:
Initially configured to return a diagnostic report, and to reset the device to factory defaults
Physical Characteristics
Housing:
Metal
Weight:
•
UC-8112-ME-T-LX: 530 g (1.18 lb)
•
UC-8112-ME-T-LX-US: 590 g (1.31 lb)
Dimensions:
141 x 119.9 x 36 mm (5.56 x 4.72 x 1.42 in)
Mounting:
DIN rail
Environmental Limits
Operating Temperature:
Wide Temp. Models:
-40 to 85°C (-40 to 185°F)
Wide Temp. models (with LTE accessory):
-40 to 70°C (-40 to 158°F)
Storage Temperature:
-40 to 80°C (-40 to 176°F)
Ambient Relative Humidity:
5 to 95% (non-condensing)
Anti
-Vibration: 2 Grms @ IEC 60068-2-64, random wave, 5-
500 Hz, 1 hr per axis (without any USB devices
attached)
Anti
-Shock: 20 g @ IEC 60068-2-27, half sine wave, 30 ms
Содержание
- Edition 1 june 2016 1
- Uc 8112 me t series hardware user s manual 1
- Www moxa com product 1
- Copyright notice 2
- Disclaimer 2
- Technical support contact information 2
- Trademarks 2
- Uc 8112 me t series hardware user s manual 2
- Www moxa com support 2
- Table of contents 3
- Introduction 4
- Model descriptions 5
- Overview 5
- Package checklist 5
- Product features 5
- Uc 8112 me t series introduction 5
- Computer 6
- Environmental limits 6
- Ethernet interface 6
- Hardware specifications 6
- Physical characteristics 6
- Serial communication parameters 6
- Serial interface 6
- Serial signals 6
- Storage 6
- Switches and buttons 6
- Uc 8112 me t series introduction 6
- Hardware block diagram 7
- Power requirements 7
- Reliability 7
- Standards and certifications 7
- Uc 8112 me t series introduction 7
- Warranty 7
- Hardware introduction 8
- Appearance 9
- Dimensions units mm in 9
- Uc 8112 me t series hardware introduction 9
- Blinking 10
- Default programmable button operations 10
- Green led 10
- Led indicators 10
- On no action 10
- Red led 10
- Uc 8112 me t series hardware introduction 10
- Attention 11
- Bdiagnosing device and subsystem failures 11
- Diagnosing device and subsystem failures 11
- Hardware defects 11
- Real time clock 11
- Reset to factory default 11
- System operation 11
- Uc 8112 me t series hardware introduction 11
- Din rail mounting 12
- Placement options 12
- Uc 8112 me t series hardware introduction 12
- Warning 12
- Hardware connection description 13
- Attention 14
- Connecting the power 14
- Grounding the unit 14
- Terminal block 14
- Uc 8112 me t series hardware connection description 14
- Wiring requirements 14
- Attention 15
- Connecting to the console port 15
- Connecting to the network 15
- Uc 8112 me t series hardware connection description 15
- Attention 16
- Connecting to a serial device 16
- Inserting the sd and sim card 16
- Uc 8112 me t series hardware connection description 16
- Usb port 16
- Installing the cellular module 17
- Uc 8112 me t series hardware connection description 17
- Uc 8112 me t series hardware connection description 18
- Uc 8112 me t series hardware connection description 19
- Uc 8112 me t series hardware connection description 20
- Uc 8112 me t series hardware connection description 21
- Uc 8112 me t series hardware connection description 22
- A regulatory approval statements 23
- Regulatory approval statements 23
- Warning 23
Похожие устройства
- Moxa UC-8112-LX-CG Технические характеристики
- Moxa UC-8132-LX-CG Инструкция по эксплуатации
- Moxa UC-8132-LX-CG Руководство по аппаратной части
- Moxa UC-8132-LX-CG Технические характеристики
- Moxa UC-8410A-LX Инструкция по эксплуатации
- Moxa UC-8410A-LX Руководство по быстрой установке
- Moxa UC-8410A-LX Руководство по аппаратной части
- Moxa UC-8410A-LX Технические характеристики
- Moxa UC-8410A-T-LX Инструкция по эксплуатации
- Moxa UC-8410A-T-LX Руководство по аппаратной части
- Moxa UC-8410A-T-LX Руководство по быстрой установке
- Moxa UC-8410A-T-LX Технические характеристики
- At Laser AQUARIUS Руководство пользователя
- Candy CCG 6102 SW Инструкция по эксплуатации
- Candy CCV 5503 W Инструкция по эксплуатации
- Candy CCV 5503 BX Инструкция по эксплуатации
- Candy FCL 624 BA Инструкция по эксплуатации
- Candy FVPE 729/6 X DISP Инструкция по эксплуатации
- Candy FCL 624/6 BA Инструкция по эксплуатации
- Candy GO4W 6423D-07 Инструкция по эксплуатации