Moxa V2416A-C2 [8/46] Environmental limits

Moxa V2416A-C2-CT-T [8/46] Environmental limits
V2416A Hardware Introduction
1-4
Dimensions:
Without ears: 250 x 86 x 154 mm (9.84 x 3.38 x 6.06 in)
With ears: 275 x 92 x 154 mm (10.83 x 3.62 x 6.06 in)
Mounting: DIN rail, wall, VESA
Environmental Limits
Operating Temperature*:
Standard models: -25 to 55°C (-13 to 131°F)
Wide temp. models: -40 to 70°C (-40 to 158°F)
Storage Temperature*: -40 to 85°C (-40 to 185°F)
*without HDD installed
Ambient Relative Humidity: 5 to 95% (non-condensing)
Anti-Vibration: EN 50155 standard
Anti-Shock: EN 50155 standard
Conformal Coating: Available on request
Power Requirements
Input Voltage: 12 to 48 VDC (M12 A-coded)
Note: Compliant with EN 50155 at 24 VDC
Power Consumption:
• 3.30 A @ 12 VDC, 39.6 W
• 0.82 A @ 48 VDC, 39.4 W
Standards and Certifications
Safety: UL 60950-1, CSA C22.2 No. 60950-1-07, EN 60950-1
EMC: EN 55022 Class A, EN 61000-3-2 Class D, EN 61000-3-3, EN 55024, FCC Part 15 Subpart B Class A
Green Product: RoHS, CRoHS, WEEE
Rail Traffic: EN 50155*, EN 50121-2-3, EN 50121-4, IEC 61373
*Complies with a portion of EN 50155 specifications. Please contact Moxa or a Moxa distributor for details.
Reliability
Automatic Reboot Trigger: Software-programmable watchdog timer configurable from 1 to 255 seconds
Warranty
Warranty Period: 3 years
Details: See www.moxa.com/warranty
Note: These hardware specifications describe the embedded computer unit itself, but not its official
accessories. In particular, the wide temperature specification does not apply to accessories such as power
adapters and cables.