TC-6110 / Windows 7 Installing Moxa Software
4-7
4. When the installation is finished, click Close to complete the installation. Please remember that the PdM
diagnostics package will not be available until the computer is rebooted. You may restart the computer at
this point, if you wish.
Configuring and Using the G-Sensor Tool
Launching the Charting Application
Follow these steps to launch and check the sensor tool.
1. To launch the G sensor charting utility, right-click on the tricolor icon in the
system tray and select GSensorChart from the pop-up menu. Please note
that if you select Exit you will shut down the Moxa PdM utilities package. If
this happens and you want to re-launch the utility, navigate to the
Windows Start Menu and select Moxa Predictive Maintenance
Diagnostic Tool from the software listed there.
ATTENTION
Users are advised that the accelerometer script returns vibration readings in milligravities (mG).
The
G
-sensor’s raw values, however, are returned in an unconve
rted hexadecimal form. If you would like to directly
access the G
-sensor data in a human-readable form, then you should access G-
sensor data from the GUI, using
the log file.
2. Next, verify that each initial value (X-axis, Y-axis, Z-axis) is close to 0 (+-100). The X-axis represents
front-to-back motion (relative t to the sensor), the Y-axis is left-to-right, and the Z-axis is up-and-down. A
good target threshold to start off with is 1000 mG.