Moxa TC-6110-W7E [37/74] Using synmap to control the programmable leds

Moxa TC-6110-LX [37/74] Using synmap to control the programmable leds
TC-6110 / Windows 7 Installing Moxa Software
4-23
Using Synmap to Control the Programmable LEDs
The following figure shows the locations of the LED indicators on the TC-6110 computer. Using custom scripts,
you can set these LEDs to be used as indicators for your own applications.
The following table shows the available OIDs for the TC-6110 LEDs.
Item Name OID Access Values Description
ledNumber 1.3.6.1.4.1.8691.17.1.6.2.1 read-only N/A Returns the total number of
LEDs
ledIndex 1.3.6.1.4.1.8691.17.1.6.2.2.1.1 read-only N/A Returns a list of numbers that
correspond with the LEDs,
used by SNMP to identify the
LEDs; begins with 1
ledPort 1.3.6.1.4.1.8691.17.1.6.2.2.1.2 read-only N/A Returns the names by which
the index of LEDs may be
called when used in scripts;
begins with 0
ledValue 1.3.6.1.4.1.8691.17.1.6.2.2.1.3 read-write 0(off), 1(on) Returns/sends a value
indicating/changing the LED
state
Follow these steps to configure the programmable LED indicators on the TC-6110 computer.
1. Start up MXview (or some other NMS) and open
the MIB browser. For detailed instructions on
loading MXview, you may refer to
Loading the
Synmap MIB File, steps 1 to 3.
2. In the MIB browser, navigate the OID tree to
MOXA-SYS-MIB\VALUES\Moxa\
embeddedComputer\MoxaSystem\
peripheralMgmt\perLedMgmt\ledTable\
ledEntry\ledValue
. To change the state of
an LED from on to off (or vice versa) click Set on
the corresponding ledValue OID (shown in the
figure at right). This will open a dialog called the
Set Value dialog.
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED8