Moxa ioLogik E1512-M12-CT-T [13/62] Connecting the power
![Moxa ioLogik E1510-M12-T [13/62] Connecting the power](/views2/1201153/page13/bgd.png)
ioLogik E1500 Series Initial Setup
2-2
Hardware Installation
Connecting the Power
Connect the 12 to 48 VDC power line to the terminal block on the top panel of the ioLogik E1500. If power is
properly supplied, the Power LED will glow a solid amber color.
ATTENTION
•
Disconnect the power cord before installing or wiring your ioLogik E1500.
•
Do not exceed the maximum current for the wiring
•
Determine the maximum possible current for each power wire and common wire. Observe all electrical
codes dictating the maximum current allowable for each wire size. If the current exceeds the maximum
rating, the wiring could overheat, causing serious damage to your equipment. For safety reasons, we
recommend an average cable size of 22 AWG. However, depending on the current load, you may want to
adjust your cable size (the maximum wire size for power connectors is 2 mm).
Grounding the ioLogik E1500
The ioLogik E1500 is equipped with a grounding point on the terminal block located on the top panel. Connect
the ground pin ( ) if earth ground is available.
Connecting to the Network
The ioLogik E1500 uses an M12-to-RJ45 Cat 5e UTP Ethernet cable for connecting to either the host PC or
another ioLogik device. The M12 connector ensures a tight, robust connection, and guarantees reliable
operations even for applications that are subject to high vibration and shock.
For initial setup of the ioLogik E1500, it is recommended that the ioLogik E1500 be configured using a direct
connection to a host computer rather than remotely over the network.
Configure the host PC’s IP address to 192.168.127.xxx (where xxx ranges from 001 to 253). When using
Windows, you will need to do the configuration from the Control Panel.
ioLogik E1500 Default IP Address Default Netmask Default Gateway
192.168.127.254 255.255.255.0 None
Use the web console or ioSearch configuration utility to connect to the ioLogik E1500. Once the ioLogik E1500
has been detected, modify the settings as needed for your network environment, and then restart the server.
Refer to Chapters 3 and 4 or further details.
Содержание
- Fourth edition january 2015 1
- Iologik e1500 series user s manual 1
- Www moxa com product 1
- Copyright notice 2
- Disclaimer 2
- Iologik e1500 series user s manual 2
- Technical support contact information 2
- Trademarks 2
- Www moxa com support 2
- Table of contents 3
- Introduction to the iologik e1500 5
- Common specifications 6
- Inside the box 6
- Iologik e1500 series introduction to the iologik e1500 6
- Ordering information 6
- Physical characteristics 6
- Power requirements 6
- Product features 6
- Specifications 6
- Digital input 7
- Environmental limits 7
- Inputs and outputs 7
- Iologik e1500 series introduction to the iologik e1500 7
- Iologik e1510 t 7
- Power requirements 7
- Standards and certifications 7
- Warranty 7
- Digital input 8
- Digital output 8
- Inputs and outputs 8
- Iologik e1500 series introduction to the iologik e1500 8
- Iologik e1512 t 8
- Power requirements 8
- Physical dimensions 9
- Hardware reference 10
- Iologik e1500 series introduction to the iologik e1500 10
- Led indicators 10
- Panel guide 10
- Di circuit dio channels 11
- Do circuit dio channels 11
- I o circuit diagram 11
- Iologik e1500 series introduction to the iologik e1500 11
- Isolation di di channels 11
- Initial setup 12
- Attention 13
- Connecting the power 13
- Connecting to the network 13
- Grounding the iologik e1500 13
- Hardware installation 13
- Iologik e1500 series initial setup 13
- Di dry contact mode 14
- Di wet contact mode ch ch isolation 14
- I o wiring diagrams 14
- Iologik e1500 series initial setup 14
- Di wet contact pnp npn mode no ch ch isolation 15
- Dio_di wet contact mode no ch ch isolation 15
- Iologik e1500 series initial setup 15
- Dio_do sink mode 16
- Iologik e1500 series initial setup 16
- Load factory defaults 16
- Software installation 16
- Using the web console 17
- Introduction to the web console 18
- Iologik e1500 series using the web console 18
- General settings 19
- Iologik e1500 series using the web console 19
- Network settings 19
- Overview 19
- Ethernet configuration 20
- Iologik e1500 series using the web console 20
- User defined modbus addressing 20
- Active opc server settings 21
- Attention 21
- Default address 21
- Iologik e1500 series using the web console 21
- Tag generation 21
- Iologik e1500 series using the web console 22
- Di channels 23
- I o settings 23
- Iologik e1500 series using the web console 23
- Iologik e1500 series using the web console 24
- Iologik e1500 series using the web console 25
- Do channels 26
- Iologik e1500 series using the web console 26
- Iologik e1500 series using the web console 27
- Iologik e1500 series using the web console 28
- Ip accessibility 28
- System management 28
- To allow access to a specific ip address 28
- To allow access to hosts on a specific subnet 28
- To allow unrestricted access 28
- Firmware update 29
- Import system configuration settings 29
- Iologik e1500 series using the web console 29
- Network connection 29
- Attention 30
- Change password 30
- Export system configuration settings 30
- Iologik e1500 series using the web console 30
- Load factory defaults 30
- Iologik e1500 series using the web console 31
- Save restart 31
- Using iosearch 32
- Introduction to iosearch 33
- Iologik e1500 series using iosearch 33
- Iosearch main screen 33
- Main screen overview 33
- Iologik e1500 series using iosearch 34
- Main items 34
- System 34
- Iologik e1500 series using iosearch 35
- Main function 35
- Quick links 35
- Attention 36
- Batch upgrades on multiple devices of the same model 36
- Firmware upgrade 36
- Iologik e1500 series using iosearch 36
- Locate 36
- Unlock 36
- Export 37
- Import 37
- Iologik e1500 series using iosearch 37
- Batch tcp ip configuration of multiple devices 38
- Change ip address 38
- Iologik e1500 series using iosearch 38
- Iologik e1500 series using iosearch 39
- Reset to default 39
- Restart system 39
- Iologik e1500 series using iosearch 40
- Mass deployment export 40
- Mass deployment import 40
- Active opc server utility 41
- Active opc server 42
- Active opc server system requirements 42
- Iologik e1500 series active opc server utility 42
- Ole for process control 42
- Active opc server from pull to push 43
- Iologik e1500 series active opc server utility 43
- Heartbeat every x seconds 44
- Iologik e1500 series active opc server utility 44
- Push for tag updates 44
- Faster more accurate data collection than traditional pull 45
- Faster more accurate data collection than traditional pull technology 45
- Features of active opc server 45
- Iologik e1500 series active opc server utility 45
- One simple click creates active tags 45
- Technology 45
- Active opc server overview 46
- Installing active opc server 46
- Iologik e1500 series active opc server utility 46
- Main screen overview 46
- Menu bar 46
- Iologik e1500 series active opc server utility 47
- System 47
- Iologik e1500 series active opc server utility 48
- Quick links 48
- A modbus tcp default address mappings 49
- Modbus tcp default address mappings 49
- E1510 user defined modbus 50
- Fixed dynamic default addresses 50
- Iologik e1500 series modbus tcp default address mappings 50
- Xxxx read write coils support function 1 5 15 50
- Iologik e1500 series modbus tcp default address mappings 51
- Xxxx read only coils support function 2 51
- Iologik e1500 series modbus tcp default address mappings 52
- Xxxx read only registers support function 4 52
- Iologik e1500 series modbus tcp default address mappings 53
- E1512 user defined modbus 54
- Fixed dynamic default addresses 54
- Iologik e1500 series modbus tcp default address mappings 54
- Xxxx read write coils support function 1 5 15 54
- Iologik e1500 series modbus tcp default address mappings 55
- Xxxx read only coils support function 2 55
- Iologik e1500 series modbus tcp default address mappings 56
- Xxxx read only registers support function 4 56
- Xxxx read write registers support function 3 6 16 56
- Iologik e1500 series modbus tcp default address mappings 57
- B network port numbers 58
- Iologik e1500 network port usage 58
- Network port numbers 58
- C factory defaults 59
- Factory defaults 59
- D pinouts 60
- Pin assignment of terminal blocks 60
- Pinouts 60
- E fcc interference statement 61
- Fcc interference statement 61
- Federal communication commission warning 61
- F european community ce 62
Похожие устройства
- Moxa ioLogik E1512-M12-CT-T Руководство по аппаратной части
- Moxa ioLogik E1512-M12-CT-T Технические характеристики
- Moxa ioLogik E1512-M12-CT-T Брошюра
- Moxa ioLogik E4200 Инструкция по эксплуатации
- Moxa ioLogik E4200 Руководство по аппаратной части
- Moxa ioLogik E4200 Технические характеристики
- Moxa ioLogik E4200 Брошюра
- Moxa NA-4010 Инструкция по эксплуатации
- Moxa NA-4010 Руководство по аппаратной части
- Moxa NA-4010 Технические характеристики
- Moxa NA-4010 Брошюра
- Moxa NA-4020 Инструкция по эксплуатации
- Moxa NA-4020 Руководство по аппаратной части
- Moxa NA-4020 Технические характеристики
- Moxa NA-4020 Брошюра
- Moxa NA-4021 Инструкция по эксплуатации
- Moxa NA-4021 Руководство по аппаратной части
- Moxa NA-4021 Технические характеристики
- Moxa NA-4021 Брошюра
- Moxa M-7001 Технические характеристики