Moxa ioPAC 8020-5-M12-C-T [12/69] Environmental limits

Moxa ioPAC 8500-2-M12-C-T [12/69] Environmental limits
Moxa C Programmable RTU Controllers Introduction
1-8
Relay Output
Type:
Form A (N.O.) power relay
Contact Current Rating:
• Resistive Load: 1 A @ 30 VDC, 250 VAC, 110 VAC
Initial Insulation Resistance:
1000 m ohms (min.) @ 500 VDC
Mechanical endurance:
5,000,000 operations
Electrical endurance:
600,000 operations @ 1 A resistive load
Contact
Resistance: 100 m ohms (max.)
Pulse Output:
0.3 Hz at rated load
Power Requirements
Power Input:
24 VDC nominal, 12 to 36 VDC
Power Consumption:
ioLogik W5348
-HSDPA-C:
• Always on: 196 mA @ 24 VDC
• On demand: 189 mA @ 24 VDC
Physical Characteristics
Dimensions:
46.8 x 135 x 105 mm (1.84 x 5.31 x 4.13 in)
Weight:
495 g
Mounting:
DIN-rail (standard), wall (optional)
Environmental Limits
Operating Temperature:
Standard Models:
-10 to 55°C (14 to 131°F)
Wide Temp. Models:
ioLogik W5348
-HSDPA-C: -20 to 70°C (-4 to 158°F)
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity:
5 to 95% (non-condensing)
Altitude:
Up to 2000 m
Note: Please contact Moxa if you require products guaranteed to function
properly at higher altitudes.
Standards and Certifications
Safety:
UL 508, EN 60950-1, NCC
EMI:
EN 55022; EN 61000
-3-2; EN 61000-3-3;
FCC Part 15, Subpart B, Class A
EMS:
EN 55024, EN 61000
-4-2, EN 61000-4-3,
EN 61000
-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000
-4-8, EN 61000-4-11, EN 61000-6-2
Mobile Network:
PTCRB
Shock:
IEC 60068-2-27
Freefall:
IEC 60068-2-32
Vibration:
IEC 60068-2-6
Green Product:
RoHS, CRoHS, WEEE
Note: Please check Moxa’s website for the most up
-to-date certification status.
MTBF (mean time between failure)
Time:
ioLogik W5348
-HSDPA-C: 280,739 hrs.
Database:
Telcordia (Bellcore)
Warranty
Warranty Period:
2 years*
*Because of the limited lifetime of power relays, products that use that component are covered by a 2
-year
warranty.
Details:
See www.moxa.com/warranty